UTZ-SC0287_3
2012/10/02
]
Ultra Violet Laser Diode
Engineering Sample
NDU7216E
Outline Dimension
ꢀFeatures
• Optical Output Power: 200mW
Unit (mm)
Φ
• Can Type:
• Peak Wavelength: 375nm
φ 5.6 Floating Mounted with Photo Diode and Zener Diode
Φ
(90°)
ꢀ
Absolute Maximum Ratings
Emitting Point
(0.4)
Absolute Maximum
Ratings
1.0±0.1
Item
Symbol
Unit
Z+
Optical Output Power
Allowable Reverse Current
PD Reverse Voltage
Po
Ir (LD)
Vr (PD)
Tstg
250
85
mW
mA
V
Φ
Φ
4.2±0.2
3.55±0.1
Emitting Point
5
Reference Plane
Storage Temperature
-40 ~ 85
20 ~ 30
°C
°C
Operating Case Temperature
Tc
4×Φ 0.43±0.08
3
(Tc=25°C)
Symbol Min Typ. Max Unit
ꢀ
Initial Electrical/Optical Characteristics
X+
1
2
Item
Condition
CW
4
Φ
2.0±0.2
Optical Output Power
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Po
λp
Ith
Iop
η
Vop
θ//
θ⊥
-
370
-
-
200 mW
Y+
Po=200mW
CW
375
200
390
1.1
4.4
19
380
260
480
1.8
5.0
25
nm
mA
mA
W/A
V
Pin Connection
Po=200mW
CW
-
0.8
-
Po=200mW
Parallel
Beam
9
°
Po=200mW
Divergence*
Perpendicular
30
40
45
°
Beam Pointing
Accuracy
Perpendicular Po=200mW
-5.0
0.2
-
-
5.0
2.0
∆θ⊥
°
This model has a Zener Diode built in
as a protection circuit against static
electricity.
Monitor Current**
Po=200mW
Im
mA
* Full angle at 1/e2 from peak intensity
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
ꢁ
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
ꢁ
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
ꢂHEADQUARTERS
NICHIA CORPORATION
http://www.nichia.co.jp
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
ꢂCONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-