DB LECTRO INC
N 9 3 2
31´ 23
Features
n
n
Switching capacity up to 15A.
Suitable for automation system and auxiliary automobile etc.
Contact Data
Contact Arrangement
Contact Material
1C
Au AgNi
Contact Rating (resistive)
15A/14VDC
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
210W
15VDC
50mW Max.
105
Max. Switching Current:15A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Operation
life
Electrical
Mechanical
107
Coil Parameter
Pickup
Release
Operate
Time
ms
Release
Time
ms
Coil voltage
VDC
voltage
VDC(max)
(67%of rated
voltage )
voltage
VDC(min)
(10% of rated
voltage)
Coil power
consumption
W
Coil resistance
W±10%
Max.
Max.
Rated
12
Max.
15.6
120
8
1.2
1.2
10
8
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance1)
100MW min (at 500VDC)
Item 7 of IEC255-5
1)
Dielectric Strength
Between contacts
Between contact and coil
Item 6 of IEC255-5
Item 6 of IEC255-5
50Hz 500V
50Hz 500V
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2
11ms
IEC68-2-27 Test Ea method 1
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
10~55Hz double amplitude 1.5mm
8N
IEC68-2-20 Test Ta method 1
230 ºC±2 ºC 10±0.5s
-40~125 ºC
85% (at 40 ºC)
IEC68-2-3Test Ca
31g
Note: 1). When testing, coil terminals shall be connect ,if coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table IV of IEC255-19-1 and minimum sample size 24.
107