MUR1620CA THRU MUR1660CA
16A Super Fast Recovery
Rectifiers - 200V-600V
Package outline
Features
• Dual rectifier construction, positive centetap, offer 8.0A
Half wave and 16.0A full wave rectification.
• High surge current capability.
TO-220AB
0.419(10.63)
0.377(9.57)
0.196(5.00)
0.163(4.16)
0.058(1.47)
0.042(1.07)
• Super fast recovery time for switching mode application.
• Low power loss.
• Glass passivated chip junctions.
0.269(6.85)
0.226(5.75)
• Lead-free parts meet environmental standards of
MIL-STD-19500/228
0.624(15.87)
0.548(13.93)
0.139(3.54)
MIN
1
2
3
0.177(4.50)MAX
Mechanical data
0.038(0.96)
0.019(0.50)
0.50(12.70)MIN
0.025(0.65)MAX
• Epoxy : UL94-V0 rated flame retardant
• Case : JEDEC TO-220AB molded plastic body over
passivated chip
0.1(2.54)
• Lead : Axial leads, solderable per MIL-STD-202,
Method 208 guranteed
• Polarity: As marked
• Mounting Position : Any
Dimensions in inches and (millimeters)
Maximum ratings (AT TA=25oC unless otherwise noted)
SYMBOLS
MUR1620CA
MUR1660CA
PARAMETER
MUR1640CA
400
UNIT
V
VRRM
Maximum repetitive peak reverse voltage
600
420
600
200
140
200
V
V
A
VRMS
VDC
Maximum RMS voltage
280
400
16
Maximum DC blocking voltage
Maximum average forward rectified current
IO
Peak forward surge current 8.3ms
single half sine-wave(JEDEC method)
A
110
IFSM
-55 to +150
-65 to +175
Operating junction temperature range
Storage temperature range
TJ
°C
°C
TSTG
Electrical Characteristics (AT TA=25oC unless otherwise noted)
SYMBOLS
MUR1620CA
MUR1660CA
PARAMETER
MUR1640CA
UNIT
V
Maximum forward voltage per leg at IF=8 A
VF
1.30
0.98
1.70
trr
ns
Maximum reverse recovery time per leg (Note 1)
25
50
Maximum DC reverse current
at TJ =25°C
5.0
500
uA
uA
IR
at rated DC blocking voltage per leg at TJ =125°C
Thermal Characteristics
SYMBOLS
MUR1620CA
MUR1660CA
PARAMETER
MUR1640CA
UNIT
Typical thermal resistance junction to case per leg
RθJC
°C/W
2.0
Note 1: Reverse recovery time test condition, IF=0.5A, IR=1.0A, IRR=0.25A
http://www.anbonsemi.com
TEL:+86-755-23776891
FAX:+86-755-81482182
Document ID
AS-3040030
Issued Date
2003/03/08
Revised Date
2023/09/07
Revision
E
Page.
3