MTDA40A SERIES
40W Desktop Power Supply for I.T. Equipment
Wide Input Voltage 90 to 264 VAC, 47 to 63Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 5VDC Thru 48VDC
Single Output
Class I Insulation
Energy Star 2.0, CEC V, and RoHS compliance
1 Year Warranty
Approvals:
Single Output
Product Number
MTDA40A-S02
MTDA40A-S03
MTDA40A-S04
MTDA40A-S05
MTDA40A-S06
MTDA40A-S07
MTDA40A-S08
MTDA40A-S09
MTDA40A-S10
MTDA40A-S11
Output Voltage
Max. Output Current
5.00 A
Total Regulation
Maximum Output Power
5 ~ 5.99 VDC
6.5 ~ 8 VDC
8 ~ 11 VDC
11 ~ 13 VDC
13 ~ 16 VDC
16 ~ 21 VDC
21 ~ 27 VDC
27 ~ 33 VDC
33 ~ 40 VDC
40 ~ 48 VDC
5%
5%
5%
5%
5%
5%
3%
3%
2%
2%
30W
30W
35W
40W
40W
40W
40W
40W
40W
40W
5.00 ~ 3.75 A
4.375 ~ 3.18 A
3.64 ~ 3.07 A
3.07 ~ 2.50 A
2.50 ~ 1.90 A
1.90 ~ 1.48 A
1.48 ~ 1.21 A
1.21 ~ 1.00 A
1.00 ~ 0.83 A
Total Regulation is conditioned by below configuration
(S02~S05: AWG16/4FT output cable)
(S06~S08: AWG18/4FT output cable)
(S09~S11: AWG18/6FT output cable)
Electrical Characteristics
Parameter
Test Conditions
Min.
100
90
47
0
Typ.
Max.
240
264
63
Unit
VAC
VAC
Hz
W
A
A
A
A
Universal Input Voltage
Operating Voltage
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Vin=100 to 240VAC
40
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
0.8
0.52
45
90
90
40
80
87
0.5
3
83
%
%
%
Line Regulation
Load Regulation
1
7
Vin=230VAC
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Nil
%
%
mS
mS
S
110
10
150
4
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=230VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Io=Full Load, Vin=240VAC
All output
Start Up Time
2
0.5
0.5
3
1
0.75
0.04
0.3
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
No-load Power Consumption
%
mA
%/°C
W
-0.04
No load, Vin=240VAC
0.2