General Purpose Relays
Multimode Relay MT
I
I
I
I
I
2 / 3 pole 10 A, 2 CO or 3 CO contacts
DC and AC coils
Mechanical indicator as standard
Electrical indicator
New test system with front operated finger protected
push-to-test button and integral locking test tab
I
I
White write on panel
RoHS compliant (Directive 2002/95/EC)
as per product date code 0415
F0161-A
Applications
Mechanical engineering, plant control
Approvals
V
REG.-Nr. 6182,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
Contact set
2 CO or 3 CO
single cont.
micro disconnection
10 A
single cont.
10 A
bifurcated
4 A
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Limiting making capacity, max 20 ms
Contact material
240/400 VAC
2500 VA
2500 VA
20 A
500 VA
8 A
AgNi90/10
gold plated
20mV/1mA
20 A
AgNi90/10
AgNi90/10
gold plated
20mV/1mA
20x106 cycles
20/100 min-1
Minimum contact load
Mechanical endurance
Rated frequency of operation with / without load
12V/10mA
Contact ratings
Type
Load
Cycles
2.2x105
6x103
MT321 10 A, 250 VAC, CO contact, cosϕ=1, 360/h, df 50%, 35°C
MT321 Ion 50 A, Ioff 5 A, 3x440 VAC, NO, cosϕ=0.3, AC15, normal cond.
MT321 Ion 30 A, Ioff 3 A, 3x440 VAC, NC, cosϕ=0.3, AC15, normal cond.
6x103
MT3..
MT2..
MT2..
2 A, 125 V, L/R 30 ms, 3 NO contacts in series, 1800/h, DF 10%
1x105
0.7 A, 125 V, L/R 20 ms, 2 NO contacts in series, 1800/h, DF 10% 2x105
1 A, 125 V, L/R 20 ms, 2 NO contacts in series, 1800/h, DF 10%
4x104
Coil data
Rated coil voltage range DC coil
AC coil
6...220 VDC
6...230 VAC
1.2 W
Coil power DC coil
AC coil
Operative range
2.3 VA
1
Coil versions, DC-coil
Coil code
STD
Rated
voltage
VDC
6
Operate
voltage
VDC
4.5
Release
voltage
VDC
0.6
Coil
Rated coil
power
W
PD*)
resistance
Ohm
006
012
024
048
060
110
220
0A6
0B2
0C4
0E8
0G0
1B0
2C0
32+10%
1.1
1.3
1.2
1.2
1.3
1.2
1.2
12
9.0
1.2
110+10%
475+10%
2000+10%
2850+10%
10000+12%
40000+15%
24
18.0
2.4
48
36.0
4.8
60
45.0
6.0
110
220
82.5
11.5
22.0
165.0
All figures are given for coil without preenergization, at ambient temperature +23°C
*) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10
1
Datasheet
Rev. EK1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2005/11
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to