5秒后页面跳转
R3-NF3 PDF预览

R3-NF3

更新时间: 2023-12-18 00:00:00
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
7页 193K
描述
Remote I/O R3 Series T-Link INTERFACE MODULE

R3-NF3 数据手册

 浏览型号R3-NF3的Datasheet PDF文件第2页浏览型号R3-NF3的Datasheet PDF文件第3页浏览型号R3-NF3的Datasheet PDF文件第4页浏览型号R3-NF3的Datasheet PDF文件第5页浏览型号R3-NF3的Datasheet PDF文件第6页浏览型号R3-NF3的Datasheet PDF文件第7页 
MODEL: R3-NF3  
0.2 to 2.5 mm , stripped length 7 mm)  
2
Remote I/O R3 Series  
Internal bus: Via the Installation Base  
(model: R3-BSx)  
T-Link INTERFACE MODULE  
(Fuji Electric T-Link capsule equivalent)  
Internal power: Via the Installation Base (model: R3-BSx)  
Power input, RUN contact output: M3 separable screw  
terminal (torque 0.5 N·m)  
27.5  
(1.08)  
Screw terminal: Nickel-plated steel  
Isolation: T-Link to internal bus or internal power to power  
input to RUN contact output to FG  
Input error data setting: Input value setting at input module  
error with side DIP SW  
130  
(5.12)  
Dual communication setting: Set with the side DIP switch  
Data allocation setting: Set with the side DIP switch  
I/O Points setting: Set with the front DIP switch  
Data setting: Set with the front DIP switch  
I/O Module Status setting: Set with the front DIP switch  
I/O Type setting: Set with the front DIP switch  
Analog Data Type setting: Set with the front DIP switch  
RUN indicator: Bi-color (green/red) LED; Green ON in normal  
communication; Red blinks when receiving data (Function  
selected with DIP SW)  
109  
(4.29)  
mm (inch)  
MODEL: R3–NF3–[1][2]  
ORDERING INFORMATION  
• Code number: R3-NF3-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R3-NF3-M2/Q)  
ERR indicator: Bi-color (green/red) LED; Green ON in  
communication errors or minor failure, blinks at errors in the  
internal circuits; Red blinks when transmitting data  
(Function selected with DIP SW)  
• Specify the specification for option code /Q  
(e.g. /C01)  
RUN CONTACT OUTPUT  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
[1] POWER INPUT  
N: No power supply  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA or 150 W  
Minimum load: 1 V DC @ 1 mA  
AC Power  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)*  
Mechanical life: 2 × 10 cycles (rate 300 cycles/min.) When  
7
DC Power  
driving an inductive load, external contact protection and  
noise quenching recommended.  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *  
* Not selectable for use with independent power modules or  
network modules with the internal power input options.  
T-Link SPECIFICATIONS  
Node address: Rotary switch; 00 – 99  
Configuration: Multi-drop  
[2] OPTIONS  
blank: none  
Communication: Half-duplex  
Baud rate: 500 kbps  
/Q: With options (specify the specification)  
Transmission media/distance:  
KPEV-SB, 0.75 mm  
2
× 1 pair, 700 m  
× 1 pair, 1000 m  
T-KPEV-SB, 1.25 mm  
2
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
INSTALLATION  
Power consumption  
AC: ≤ 22 VA  
/C02: Polyurethane coating  
/C03: Rubber coating  
DC: ≤ 9 W  
Current consumption (no power supply): 120 mA  
Output current (power supply): 230 mA continuous at 20 V  
DC; 380 mA for 10 minutes  
GENERAL SPECIFICATIONS  
Connection  
T-Link: Euro type connector terminal (applicable wire size:  
R3-NF3 SPECIFICATIONS  
ES-8288 Rev.2 Page 1/7  
http://www.m-system.co.jp/  

与R3-NF3相关器件

型号 品牌 描述 获取价格 数据表
R3-NF3-M2 MSYSTEM Remote I/O R3 Series T-Link INTERFACE MODULE

获取价格

R3-NF3-M2/Q MSYSTEM Remote I/O R3 Series T-Link INTERFACE MODULE

获取价格

R3-NF3-R MSYSTEM Remote I/O R3 Series T-Link INTERFACE MODULE

获取价格

R3-NF3-R/Q MSYSTEM Remote I/O R3 Series T-Link INTERFACE MODULE

获取价格

R3-NFL1 MSYSTEM Remote I/O R3 Series FL-net INTERFACE MODULE

获取价格