APPLICABLE STANDARD
OPERATING
STORAGE
-40C TO +85C
2 W
-40C TO +85C
TEMPERATURE RANGE
TEMPERATURE RANGE
CHARACTERISTIC
IMPEDANCE
OPERATING HUMIDITY
RANGE
RATING POWER
FREQUENCY
RANGE
50Ω
0.045 TO 6 GHz
TO 90%
APPLICABLE
CABLE
PECULIARITY
-
-
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
×
×
ELECTRIC CHARACTERISTICS
CENTER CONTACT 100 m
.
CONTACT RESISTANCE
100 mA MAX (DC OR 1000 Hz).
MAX
×
×
100 m MAX.
※1
OUTER CONTACT
INSULATION RESISTANCE
100 V DC.
1000 M MIN.
-
×
×
VOLTAGE PROOF
V.S.W.R.
100 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
×
FREQUENCY
FREQUENCY
FREQUENCY
FREQUENCY
0.045 TO 3.0 GHz
1.4
1.6
MAX
MAX
※1
×
-
3.0 TO 6.0 GHz
0.045 TO 3.0 GHz
3.0 TO 6.0 GHz
INSERTION LOSS
ISOLATION
0.5 dB MAX.
0.7 dB MAX.
※1
×
-
-
-
FREQUENCY
TO
GHz
dB MIN.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
100000 TIMES INSERTIONS AND EXTRACTIONS.
1) ACCORDING TO THE V.S.W.R.
AND THE INSERTION LOSS SPEC. ABOVE. ※2
2) NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
-
×
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
RO.FURUYAMA
CHECKED
DATE
△
1
1
DIS-D-00004024
NK.NINOMIYA
20190509
20170324
20170324
20170324
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KH.IKEDA
※1. This specification includes MS-180 and HRM.J-ML51.P-A(40).
2. V.S.W.R. and Insertion loss spec is measured with MS-180
which is not used in mechanical operation test.
NK.NINOMIYA
RO.FURUYAMA
RO.FURUYAMA
20170324
Unless otherwise specified, refer to IEC-60512.
Note QT:Qualification Test AT:Assurance Test ×:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-373693-00-00
MS-180-ML51.J-F6
SPECIFICATION SHEET
1
1/1
HIROSE ELECTRIC CO., LTD.
CL358-0362-0-00
△
FORM HD0011-2-1