MPV40RHISeries
Compact, 6:1 Input
PV Power 40W
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 40W Output Power
Input
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
Conditions
Min.
200
185
175
Typ.
600
Max.
1,200
195
185
320
100
55
Units
VDC
VDC
VDC
• 200 - 1200 VDC Input Range
• 4,000 VDC Isolation
• Input Under Volt Protection
• Output Over Volt Protection
• Compact Case
200 VDC Input
Input Current
600 VDC Input
1200 VDC Input
600 VDC Input
mA
Inrush Current
Start-Up Time
Output
60
A
mS
500
• -25°C to +70°C Operation
• >300 kHours MTBF
Parameter
Conditions
Min.
Typ.
1.0
0.5
Max.
2.0
1.0
1.0
200
Units
%
%
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Power Protection
Output Short Circuit
General
VIN = MIN to MAX
IOUT = 5% to 100%
See Note 1
0.5
%
100
0.02
110
mV P - P
%/°C
%IOUT
Autorecovery
Continuous (Autorecovery)
Parameter
Conditions
Min.
Typ.
Max.
Units
VDC
kHz
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
60 Seconds 4,000
65
Standard
See Note 2
See Note 2
Min.
EN 55022
Typ.
Max.
Class A
Class A
Units
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Criteria B; 6 kV/ 8
Criteria A; 10V/m
Criteria B; 4 kV
See Note 3
See Note 4
Criteria B; 2 kV
Criteria A; 10 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
PFM
Voltage Dips
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Conditions
Min.
-25
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Ambient
Free Air Convection
RH, Non-condensing
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
95
%
Physical
Case Size
Case Material
Weight
See Mechanical Drawings (Page 4)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
7.98 Oz (225g)
T: (781) 344-8226
F: (781) 344-8481
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
300
Typ.
Max.
Units
kHours
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Wave Soldering (5-10S)
Manual Soldering (3-5S)
Min.
255
350
Typ.
260
360
Max.
265
370
Units
Lead Temperature, See Note 5
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.