MPV4080Series
PV Power, 40W
200 - 1500V Input
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 40W Output Power
Parameter
Conditions
Min.
200
180
170
Typ.
Max.
1,500
195
185
320
80
Units
VDC
VDC
VDC
• 200 - 1500 VDC Input Range
• 4,000 VAC Isolation
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
• Input Under Volt Protection
• Output Over Volt Protection
• Short Circuit Protection
• -40°C to +70°C Operation
• >300 kHours MTBF
200 VDC Input
Input Current
Inrush Current
800 VDC Input
1500 VDC Input
200 VDC Input
800 VDC Input
1500 VDC Input
mA
42
30
80
150
A
S
Start-Up Time
2.0
Output
Parameter
Conditions
Min.
Typ.
2.0
1.0
1.0
150
0.02
Max.
Units
%
%
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Power Protection
Output Short Circuit
General
VIN = MIN to MAX
IOUT = 0% to 100%
See Note 1
%
300
320
mV P - P
%/°C
%IOUT
Autorecovery
Continuous (Autorecovery)
120
Parameter
Conditions
Standard
Min.
Typ.
Max.
Units
VAC
kHz
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
60 Seconds 4,000
65
Criteria
Level
Radiated Emissions, See Note 2
Conducted Emissions, See Note 2
ESD
EN 55022
EN 55022
Class A
Class A
6 kV/ 8
10V/m
2 kV
1 kV
10 Vrms
10 A/m
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
B
A
B
B
A
A
RS
EFT, See Note 3
Surge, See Note 4
CS
PFM
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Conditions
Min.
-40
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Ambient
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
See Mechanical Drawings (Page 3)
Black, Flame Retardant, Non-Conductive Plastic (UL94-V0)
14.54 Oz (410g)
Weight
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
Conditions
Wave Soldering (5-10S)
Manual Soldering (3-5S)
Min.
255
350
Typ.
260
360
Max.
265
370
Units
Lead Temperature, See Note 5
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com