PTC Resettable Fuse
Radial Leaded Type
MPTH Series
FEATURE
Operation Current: 80mA to 400mA
Maximum Interrupt Voltage: 250V / 600V
Temperature Range: -40ºC to 85ºC
Low hold current Solid State
Wide variety of electronic applications
UL/cUL safety approved: certification No: E223037
TUV safety approved: certification No: R50223766
PART NUMBERING SYSTEM
MPTH 250V 080 V
(1)
(2)
(3)
(4)
No
(1)
(2)
(3)
(4)
Item
Digit
MPTH
250V
080
Description
Series Reference
Radial Lead Type
Meritek Series
Voltage Rating
Current Rating
Internal Code
Polymer Resettable Fuse Series
250V: 250VDC
300V: 300VDC
080: 80mA
110: 110mA,
V
V: High Operating Voltage
X: Round Type, M: Special Type
ELECTRICAL CHARACTERISTICS AT 23ºC
Item
Value
Characteristics
Hold Current
IH=Hold current-maximum current at which the device will not trip at 23ºC still air.
IT=Trip current-minimum current at which the device will always trip at 23ºC still air.
0.08A
Trip Current
0.16A
60VDC
3.0A
V MAX=Maximum voltage device can withstand without damage at its rated current
(I MAX).
Rated Voltage
Max Current
I MAX= Maximum fault current device can withstand without damage at rated voltage
(V MAX).
Pd=Typical power dissipated-type amount of power dissipated by the device when in
Typical Power
Max Time to Trip
1.0W
the tripped state in 23ºC still air environment.
Device response time, at current 0.35A
4.0Sec.
RMIN=Minimum device resistance at 23ºC prior to tripping.
RMIN
R1MAX
14.0 Ω
33.0 Ω
Resistance
R1MAX=Maximum device resistance at 23ºC measured 1 hour after tripping or reflow
soldering of 260ºC for 20 seconds.
Physical specifications:
o
o
o
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement.
Lead material: Tin plated copper, 22 AWG.
All MPTH products are designed to assist equipment to pass ITU, UL1950 or GR1089 specification.
MPTH150-600M, MPTH160-600V meet UL497A Overvoltage and Endurance Conditioning requirements for Thermistor type component.
CAUTION: MPTH devices are not intended for continuous use of Line Voltage such as 120VAC ~ 600VAC and above.
Rev. 7b