mps-45 ꢀerieꢀ
45W Single Output for Medical Type
ꢏꢃꢆꢍꢌꢄꢃꢅꢈꢛ
�ꢀꢁꢂꢃꢄꢅꢆꢇꢈꢉꢊꢈꢁꢀꢋꢌꢍꢈꢎꢈꢏꢌꢇꢇꢈꢄꢆꢀꢐꢃ
ꢑꢒꢓꢈꢇꢃꢆꢔꢆꢐꢃꢈꢕꢌꢄꢄꢃꢀꢍ ꢖꢗꢘꢙꢉ
ꢚꢄꢒꢍꢃꢕꢍꢁꢒꢀꢅꢛꢜꢝꢒꢄꢍꢈꢕꢁꢄꢕꢌꢁꢍꢎꢞꢂꢃꢄꢈꢇꢒꢆꢟꢎꢞꢂꢃꢄꢈꢂꢒꢇꢍꢆꢐꢃ
ꢊꢒꢒꢇꢁꢀꢐꢈꢠꢡꢈꢢꢄꢃꢃꢈꢆꢁꢄꢈꢕꢒꢀꢂꢃꢕꢍꢁꢒꢀ
ꢣꢖꢖꢤꢈꢢꢌꢇꢇꢈꢇꢒꢆꢟꢈꢠꢌꢄꢀꢥꢁꢀꢈꢍꢃꢅꢍ
ꢏꢁꢦꢃꢟꢈꢅꢓꢁꢍꢕꢝꢁꢀꢐꢈꢢꢄꢃꢧꢌꢃꢀꢕꢡꢈꢆꢍꢈꢨꢩꢪꢫꢬ
ꢘꢈꢡꢃꢆꢄꢅꢈꢓꢆꢄꢄꢆꢀꢍꢡ
SPECIFICATION
MODEL
MPS-45-3.3 MPS-45-5
MPS-45-7.5 MPS-45-12 MPS-45-13.5 MPS-45-15 MPS-45-24 MPS-45-27 MPS-45-48
DC�VOLTAGE
3.3V
5V
7.5V
12V
13.5V
3.3A
15V
24V
27V
48V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
8A
8A
5.4A
3.7A
3A
1.9A
1.7A
1A
0�~�10.7A
26.4W
0�~�10.5A
40W
0�~�7A
40.5W
0�~�4.4A
44.4W
0�~�3.9A
44.6W
0�~�3.5A
45W
0�~�2.2A
45.6W
0�~�1.95A
45.9W
0�~�1.1A
48W
OUTPUT�POWER�(max.)
52W(+3.3V:35W)with�18CFM�min.�Forced�air�convection
RIPPLE�&�NOISE�(max.) Note.2 80mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
OUTPUT
VOLTAGE ADJ.�RANGE
2.97�~�3.63V 4.5�~�5.5V
6.75�~�8.25V 10.8�~�13.2V 12.2�~�14.85V 13.5�~�16.5V 21.6�~�26.4V 24.3�~�29.7V 43.2�~�52.8V
VOLTAGE�TOLERANCE Note.3 3.0%
3.0%
1.0%
3.0%
3.0%
1.0%
3.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
1.0%
3.0%
800ms,�30ms/230VAC����������1200ms,�30ms/115VAC�at�full�load
50ms/230VAC����������16ms/115VAC�at�full�load
90�~�264VAC����������127�~�370VDC
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
47�~�440Hz
65%
72%
75%
76%
76%
77%
78%
78%
78%
INPUT
1.2A/115VAC����������0.7A/230VAC
COLD�START 15A/115VAC����������30A/230VAC
<0.3mA /�264VAC
53�~�75W�(3.3V:36�~�55W) rated�output�power
OVER�LOAD
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
PROTECTION
ENVIRONMENT
3.8�~�4.46V 5.75�~�6.75V 8.63�~�10.1V 13.8�~�16.2V 15.5�~�18.2V 17.25�~�20.25V 27.6�~�32.4V 31�~�36.45V 55.2�~�64.8V
OVER�VOLTAGE
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-10�~�+60 (Refer�to�output�load�derating�curve)
WORKING�TEMP.
20�~�90%�RH�non-condensing
WORKING�HUMIDITY
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
-20�~�+85 ,�10�~�95%�RH
0.04%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�Period�for�60min.each�along�X, Y,�Z�axes
VIBRATION
SAFETY STANDARDS
WITHSTAND�VOLTAGE
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
I/P-O/P:4KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG:100M�Ohms/500VDC
ISOLATION�RESISTANCE
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
SAFETY &
Compliance�to�EN55011�(CISPR11)�Class�B
EMC
(Note�4)
Compliance�to EN61000-3-2,-3
EMS�IMMUNITY
MTBF
Compliance�to EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN60601-1-2�Medical�level,�criteria A
366.1Khrs�min.������MIL-HDBK-217F�(25
127*76.2*28mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.18Kg;�72pcs/15.1Kg/1.35CUFT
ꢣꢗꢈꢉꢇꢇꢈꢋꢆꢄꢆꢙꢃꢍꢃꢄꢅꢈꢭꢞꢮꢈꢅꢋꢃꢕꢁꢆꢇꢇꢡꢈꢙꢃꢀꢍꢁꢒꢀꢃꢟꢈꢆꢄꢃꢈꢙꢃꢆꢅꢌꢄꢃꢟꢈꢆꢍꢈꢯꢘꢖꢰꢉꢊꢈꢁꢀꢋꢌꢍꢱꢈꢄꢆꢍꢃꢟꢈꢇꢒꢆꢟꢈꢆꢀꢟꢈꢯꢩ ꢒꢢꢈꢆꢙꢠꢁꢃꢀꢍꢈꢍꢃꢙꢋꢃꢄꢆꢍꢌꢄꢃꢗ
ꢯꢗꢈꢲꢁꢋꢋꢇꢃꢈꢳꢈꢀꢒꢁꢅꢃꢈꢆꢄꢃꢈꢙꢃꢆꢅꢌꢄꢃꢟꢈꢆꢍꢈꢯꢖꢴꢫꢬꢈꢒꢢꢈꢠꢆꢀꢟꢓꢁꢟꢍꢝꢈꢠꢡꢈꢌꢅꢁꢀꢐꢈꢆꢈꢣꢯꢵꢈꢍꢓꢁꢅꢍꢃꢟꢈꢋꢆꢁꢄꢥꢓꢁꢄꢃꢈꢍꢃꢄꢙꢁꢀꢆꢍꢃꢟꢈꢓꢁꢍꢝꢈꢆꢈꢖꢗꢣꢌꢢꢈꢳꢈꢨꢶꢌꢢꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢕꢆꢋꢆꢕꢁꢍꢒꢄꢗ
ꢘꢗꢈꢮꢒꢇꢃꢄꢆꢀꢕꢃꢈꢛꢈꢁꢀꢕꢇꢌꢟꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢒꢇꢃꢄꢆꢀꢕꢃꢱꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢈꢆꢀꢟꢈꢇꢒꢆꢟꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢗ
ꢨꢗꢈꢮꢝꢃꢈꢋꢒꢓꢃꢄꢈꢅꢌꢋꢋꢇꢡꢈꢁꢅꢈꢕꢒꢀꢅꢁꢟꢃꢄꢃꢟꢈꢆꢈꢕꢒꢙꢋꢒꢀꢃꢀꢍꢈꢓꢝꢁꢕꢝꢈꢓꢁꢇꢇꢈꢠꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢟꢈꢁꢀꢍꢒꢈꢆꢈꢢꢁꢀꢆꢇꢈꢃꢧꢌꢁꢋꢙꢃꢀꢍꢗꢈꢮꢝꢃꢈꢢꢁꢀꢆꢇꢈꢃꢧꢌꢁꢋꢙꢃꢀꢍꢈꢙꢌꢅꢍ ꢠꢃꢈꢄꢃꢥꢕꢒꢀꢢꢁꢄꢙꢃꢟꢈꢍꢝꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢙꢃꢃꢍꢅ
ꢷꢴꢊꢈꢟꢁꢄꢃꢕꢍꢁꢂꢃꢅꢗ
ꢩꢗꢈꢴꢒꢌꢀꢍꢁꢀꢐꢈꢝꢒꢇꢃꢅꢈꢴꢣꢈꢆꢀꢟꢈꢴꢯꢈꢅꢝꢒꢌꢇꢟꢈꢠꢃꢈꢐꢄꢒꢌꢀꢟꢃꢟꢈꢢꢒꢄꢈꢷꢴꢸꢈꢋꢌꢄꢋꢒꢅꢃꢅꢗ
300 myleꢀ standiꢀh Blvd., Taunton, mA 02780
WWW.AsTRODYNE.COm
ph: 1-800-823-8082
Fax: 508-823-8181