Series
MPO-500S
Single Output, 500W
Power Factor Corrected,
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Conditions
Min.
90
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
• 500W Power W/30 CFM
• Universal 90-264 AC Input
• >0.95 Active PFC
Universal
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
• EN 60950 Approved
• Standby 5V Output
• ThreeSingleOutputModels
• Meets EN 55022 B
• >160 kHour MTBF
35.0
70.0
0.50
Inrush Current
A Pk
mA
Safety Ground Leakage Current
Power Factor Correction, See Note 1
Output
Parameter
Max Output Power
0.95
Conditions
Min.
Typ.
Max.
Units
500W (with 30 CFM), 240W (230 VAC), 230W (115 VAC)
• Only 5.0” x 3.0” x 1.4”
Output Voltage Accuracy
Line Regulation
2.0
1.0
1.2
%
%
VIN = 115 to 264 VAC
12 VOUT
Load Regulation, See Note 2
%
24 and 48 VOUT
12 VDC Output
24 VDC Output
48 VDC Output
115 VAC, 90% VOUT
0°C - 50°C
1.0
150
240
480
Ripple & Noise (20 MHz), See Note 3
mV P - P
Hold-Up Time
8
mSec
%/°C
°C
0.03
0.06
120
Temperature Coefficient
-30°C - 0°C
Over Temperature Protection
Over Voltage Protection
Overload Protection
Short Circuit Protection, See Note 4
General
Autorecovery
See Model Selection Guide
120
170
%
Continuous (Autorecovery)
Parameter
Conditions
Input to Output
Min.
3,000
4,242
Typ.
Max.
Units
VAC
VDC
Isolation Voltage
Input to Ground 1,500
Output to Ground
VAC
kHz
500
58
Switching Frequency
EMI Characteristics
Parameter
75
Standard
Criteria
Level
Radiated Emissions
Conducted Emissions
Noise Immunity (EMS)
Surge
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
EN 55022
EN 55022
EN 55024
A
B
EN 61000-4-4
1 kV (L-N), 2 kV (L-G)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
-30
-30
Typ.
+25
Max.
+70
+85
Units
°C
°C
Ambient
Free Air Convection (See Derating Curve)/30 CFM
RH, Non-condensing 95
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Size
Weight
See Mechanical Drawing (Page 4)
16.22 Oz (0.460 kg)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
160
Typ.
Max.
Units
kHours
Safety Standards
Vibration
UL 1950, EN 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
www.micropowerdirect.com