Series
MPO-120S
Single Output, 180W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 180W Output Power
• Universal 90-264 AC Input
• Power Factor Correction
• EN 60950 Approved
• High Efficiency
Parameter
Conditions
Min.
90
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
115 VAC 0.99
30.0
60.0
Inrush Current
A Pk
• Five Single Output Models
• Meets EN 55022 B
• >120 kHour MTBF
Power Factor Correction, See Note 1
W/VA
mA
230 VAC 0.95
Safety Ground Leakage Current
Output
Parameter
0.50
Conditions
Min.
Typ.
Max.
Units
Output Voltage/Current
Output Voltage Accuracy
Line Regulation
See Model Selection Guide
2.0
%
%
%
VIN = Min to Max
1.0
1.0
Load Regulation
IOUT = 5% to 100%
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
See Model Selection Guide
115 VAC 15
mSec
%/°C
Temperature Coefficient
Over Voltage Protection
Overload Protection
Short Circuit Protection
General
0.03
>125% VOUT (Autorecovery)
See Note 3 130
Continuous (Autorecovery)
180
%IOUT
Parameter
Conditions
Input to Output
Min.
4,000
5,656
Typ.
Max.
Units
VAC
VDC
Isolation Voltage
Input to Ground 2,000
Output to Ground 500
VAC
kHz
Switching Frequency
EMI Characteristics
Parameter
65
Standard
Criteria
Level
Radiated Emissions
Conducted Emissions
Noise Immunity (EMS)
EN 55022
EN 55022
EN 55024
B
B
1 kV (L-N)
2 kV (L-FG & N-FG)
Surge
EN 61000-4-4
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Conditions
Min.
-25
-25
Typ.
+25
Max.
+70
+85
Units
°C
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing
Humidity
95
%
Physical
Size
Weight
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
See Mechanical Drawings (Page 4)
12.33 Oz (350g)
5 VOUT Model
All Other Models
9.87 Oz (280g)
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
120
Typ.
Max.
Units
kHours
MTBF
Safety Standards
Vibration
UL 1950, EN 60950 (except 5 & 15 VOUT models)
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
www.micropowerdirect.com