Electrical Specifications
Key Features:
• 24W Output Power
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• EN 60601-1 3RD Edition
• Universal 85-264 VAC Input
• EN 60950 Approved
• Reinforced Insulation
• Meets IEC Safety Class II
• Low Leakage Current
• Single and Dual Outputs
• Meets UL 508
Parameter
Conditions
Min.
85
120
47
Typ.
Max.
264
370
440
Units
VAC
VDC
Hz
Input Voltage Range
Input Frequency
115 VAC
230 VAC
20
40
Inrush Current, See Note 2
A Pk
W
No Load Power Consumption
Output
Parameter
Output Voltage Accuracy
Line Regulation
0.3
Conditions
Min.
Typ.
2.0
0.5
0.5
2.5
1.5
1.0
20
Max.
Units
%
%
VIN = Min to Max
Single Output
Load Regulation, IO = Min to Max
Ripple & Noise (20 MHz), See Note 3
Hold-Up Time
%
%VP-P of VO
mS
Dual Output
5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
230 VAC, 50 Hz
1.8
1.3
Chassis Mount Models
& DIN Rail Mount
Option Available!
80
Temperature Coefficient
Over Voltage Protection
Overshoot
Overload Protection
Over Temperature Protection
Short Circuit Protection, See Note 7
General
0.02
120
%/°C
% of VO
%
% INOM
°C
See Note 4
5
See Note 5 105
See Note 6
90
Continuous (Autorecovery)
Parameter
Isolation Voltage (Reinforced)
Leakage Current
Isolation Resistance
Switching Frequency
Environmental
Conditions Min. Typ.
Max.
Units
VAC rms
µA
M⍀
kHz
Input to Output 4,000
500 VDC 1,000
80
132
Parameter
Radiated Emissions
Conducted Emissions
Standard
EN 55014, EN 55024
EN 55022
Criterea
Level
Class B
Class B
A
A
A
A
A
A
A
A
B
8 kV Air
4 kV Contact
10 V/m
2 kV
1 kV
10 Vrms
30 A/M
30% 10 mS
95% 5,000 mS
ESD
EN 61000-4-2
RS
EFT
Surge
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
PFM
Voltage Dips
Interruptions
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling, See Note 8
Humidity
Physical
Case Size
Case Material
Reliability Specifications
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
Typ.
+25
Max.
+80
+95
Units
°C
°C
Ambient
-40
-40
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
See Mechanical Diagrams (Pages 3 & 4)
Non-Conductive Plastic Resin (UL94-V0)
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
400
kHours
Safety Standards
UL 60950, EN 60950
Safety Class
IEC 60536 Class II
www.micropowerdirect.com