Series
MPM-03MM
Miniature 1 x 1 Inch
3W, Single Output
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 3W Output Power
Parameter
Conditions
Min.
85
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
• Miniature 1 x 1 Inch Case
• Universal 85-264 VAC Input
• EN 60950 Approved
• Six Standard Models
• Meets EN 55022 B
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
15.0
25.0
150
Inrush Current, See Note 1
A Pk
mW
230 VAC
See Note 2
No Load Power Consumption
Output
Parameter
• Meets IEC Safety Class II
Conditions
Min.
Typ.
Max.
Units
• >1.20 MHour MTBF
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Overshoot
See Model Selection Guide
See Model Selection Guide
2.0
1.0
1.0
70
%
%
%
m V P-P
mS
%/°C
%VOUT
%VOUT
VIN = Min to Max
IOUT = 0% to 100%
115 VAC
8.0
0.05
190
5.0
See Note 3
125
Short Circuit Protection, See Note 4
Overload Protection
General
Continuous (Auto-Recovery)
See Note 5 135
150
%W
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
M
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Input to Output, 60S 3,000
500 VDC 100
65
kHz
Standard
Criteria
Level
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
EN 55014, EN 55024
Class B
Class B
8 kV Air
10V/m
2 kV
1 kV
10 Vrms
30A/m
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
A
A
A
A
A
A
A
B
30% 10 mS
95% 5,000 mS
Interruptions
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Conditions
Min.
-25
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing 95
Humidity
%
Physical
Case Size
T: (781) 344-8226
F: (781) 344-8481
See Mechanical Diagram (Page 2)
Case Material
Weight
Non-Conductive Black Plastic (UL94-V0)
0.59 Oz (17.4g)
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 1.20
MHours
Safety Standards
Safety Class
EN 60950
IEC 60536 Class II
www.micropowerdirect.com