Series
MPL-01SE
Single Output, 1W
Ultra-Miniature SIP
AC/DC Power Supplies
Key Features:
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 1W Output Power
Input
Parameter
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Single Regulated Output
• Meets EN 55022 Class A
• >300 kHour MTBF
Conditions
Min.
85
100
47
Typ.
Max.
264
400
63
Units
VAC
VDC
Hz
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
230 VAC
10.0
20.0
0.3
Inrush Current
A Pk
W
• Ultra-Miniature “SIP” Case
Standby Power
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
Output Voltage Accuracy, See Note 1
Line Regulation
Load Regulation
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
VIN = Min to Max
IOUT = 5% to 100%
5V, 24V Models
9V, 12V, 15V Models
230 VAC
1.5
2.5
100
80
%
%
150
120
Ripple & Noise (20 MHz)
mV P-P
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Temperature Protection
General
50
mSec
%/°C
0.01
Continuous (Autorecovery)
150
Max.
50
°C
Parameter
Conditions
Min.
Typ.
Typ.
Units
VAC
kHz
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Input to Output 3,000
Standard
Min.
Max.
Class A
Class A
Units
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips
See Note 3
See Note 3
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Criteria B; 4 kV Contact
Criteria A; 10V/m
Criteria B; 2 kV
Criteria B; 1 kV / 2 kV
Criteria A; 3 Vrms
See Note 4
See Note 5
See Note 6
See Note 7
Criteria A; 10A/m
Criteria B; 0% - 70%
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Conditions
Min.
-40
Typ.
+25
Max.
+85
+90
Units
°C
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Ambient
Case
-40
+105
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing 85
Humidity
%
Physical
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Case Size
1.38 x 0.43 x 0.94 Inches (35.0 x 11.0 x 24.0 mm)
Non-Conductive Epoxy (UL94-V0)
0.35 Oz (10g)
Case Material
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
Safety Standards
Safety Class
EN 60950
IEC 61140 Class II
www.micropowerdirect.com