65W Dual Output Medical Type
MPD-65 series
Features :
Universal AC input / Full range
Low leakage current 0.3mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
MPD-65A
MPD-65B
OUTPUT NUMBER
DC VOLTAGE
CH1
CH2
CH1
CH2
24V
2A
5V
12V
5V
RATED CURRENT
CURRENT RANGE
RATED POWER
5.5A
2.8A
3.5A
0.4 ~ 7A
61.1W
0.2 ~ 3.2A
0.4 ~ 6A
65.5W
0.2 ~ 2.6A
OUTPUT POWER (max.)
72W with 18CFM min. Forced air convection
OUTPUT
RIPPLE & NOISE (max.) Note.2 60mVp-p
150mVp-p
60mVp-p
CH1:4.5 ~ 5.5V
4.0%
150mVp-p
VOLTAGE ADJ. RANGE
CH1:4.5 ~ 5.5V
VOLTAGE TOLERANCE Note.3 4.0%
7.0%
7.0%
2.0%
4.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
1.0%
2.0%
1.0%
3.0%
4.0%
3.0%
800ms, 20ms/230VAC
800ms, 20ms/115VAC at full load
80ms/230VAC
90 ~ 264VAC
47 ~ 440Hz
75%
12ms/115VAC at full load
127 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
78%
INPUT
1.6A/115VAC
1A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 20A/115VAC
<0.3mA / 264VAC
40A/230VAC
LEAKAGE CURRENT
73 ~ 105W rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75VDC on CH1
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +55 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.04%/ (0 ~ 50 ) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL2601-1, TUV EN60601-1, IEC60601-1 approved
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG:100M Ohms/500VDC
EMC
(Note 4)
Compliance to EN55011 (CISPR11) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2, medical level, criteria A
EMS IMMUNITY
MTBF
291.3Khrs min. MIL-HDBK-217F (25
127*76*42mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.25Kg; 54pcs/16Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:MPD-65-SPEC 2008-03-25