Series
MPB-10S
Miniature PCB-Mount,
10W, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 10W Output Power
• Universal 85-264 AC Input
• EN 60950 Approved (UL)
• PCB Mountable
Input
Parameter
Conditions
Min.
85
Typ.
Max.
264
373
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
127
47
Input Frequency
Input Filter
Meets EN 55022 Class B
See Model Selection Guide
• Meets IEC Safety Class II
• Meets EN 55022 B
• High Efficiency
Input Current
Cold Start, 115 VAC
20.0
40.0
0.25
Inrush Current
A Pk
mA
Cold Start, 230 VAC
264 VAC
Safety Ground Leakage Current
Output
• >200 kHour MTBF
Parameter
Conditions
See Model Selection Guide
See Note 1 1.0
Min.
Typ.
Max.
Units
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
%
%
%
%
Vin = 100 VAC to 240 VAC
Iout = 10% to 100%
See Note 2
0.5
1.0
1.0
16
Load Regulation
Ripple & Noise (20 MHz)
115 VAC
Hold-Up Time
mSec
%/°C
230 VAC
60
Temperature Coefficient
Short Circuit Protection
General
0.05
Hiccup Mode (Autorecovery)
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
M⍀
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Input to Output 3,000
500 VDC
100
2,200
Conducted
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
Electrostatic Discharge (ESD)
RF Field Susceptibility
EMC Compliance
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-4
Surge
Fixed
IEC/EN 61000-4-5
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
100
kHz
Conditions
Min.
0
Typ.
+25
Max.
+40
Units
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Ambient
-20
+85
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing 93
Humidity
%
Physical
Size
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
2.559 x 1.772 x 0.906 Inches (65.0 x 45.0 x 23.0 mm)
2.12 Oz (0.060 kg)
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
Safety Standards
Vibration
UL 60950, EN 60950
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 10 min each along X, Y & Z Axis