MPA600RSeries
Industrial 600W
Single Output
NEW
Industrial
Power!!
Power Factor Corrected
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 600W Output Power
• Universal 90-264V AC Input
• PFC to EN61000-3-2 “D”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 2 - 56 V Output Voltages
• N+1 Current Share Option
• Three Mechanical Options
Input
Parameter
Conditions
Min.
90
47
Typ.
10
Max.
264
63
Units
VAC
Hz
Input Voltage Range
Input Frequency
Input Current, Full Load
Universal
90 - 264 VAC
110 VAC
A
17.5
35
Inrush Current, Cold Start
A
220 VAC
240 VAC
Leakage Current (Note 1)
Power Factor Correction
Input Protection
1.5
mA
Active, Meets EN61000-3-2 Class D
T10A/250V Fuse
Output
Parameter
Conditions
Min.
Typ.
5.0
1.0
20
Max.
Units
%
%
Output Voltage Adjustment
Output Regulation (Note 2)
Hold Time
By Trim Pot
80% Load
mSec
Ripple & Noise (20 MHz) (Note 3)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 4)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
See Model Selection Guide
Power Limit 110
>130% of Rated Output Voltage. Recycle AC Input.
>+85ºC Ambient with Autorecovery
0.04
140
%
%/ºC
mS
%
%
S
2.5
50% Load Change
5
At Turn On/Off
5.0
1
120 VAC
Output Short Circuit
Continuous With Autorecovery
General
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
kHz
Input - Output 3,000
Input - FG (Frame Ground) 1,500
Primary - Core 1,500
Fixed
Isolation Voltage
Switching Frequency
Interface Signals
Power Supply On
23
Green LED (LED1) on the PCB
PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
CSH on CN3. Single wired, forced current sharing option. Up to four
units may be connected in parallel within 10% accuracy at full load.
CMN on CN3. A 0.5V to 3.0V output that represents 0% to 100% of the
unit output current
Power Good Signal
Current Sharing
Current Monitor
Remote Sense
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
RS + and RS- on CN3. Compensates for up to a 0.5V line drop. (not on
models with current share option)
RSW on CN3. A TTL low signal inhibits the output
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Remote On/Off
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
Ambient
0
+25
+50
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
See Model Selection Guide
+85
90
ºC
%
RH, Non-condensing
Conditions
MIL HDBK 217F, 30ºC, Gnd Benign
Min.
150
Typ.
Max.
Units
kHours
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)