Series
MP- MS11
3-4Amp 240 Vac (AC OUTPUT) 3Amp 60 Vdc (DC OUTPUT)
• DIN Rail Mount
Solid State Relay on DIN-rail mount carrier.
Available for either AC or DC load switching.
•
Compatible with 5, 15 & 24
V
olt
L
ogi
c
S
y
s
tem
s
Internal snubber included for high dv/dt
applications (AC only).
•
•
Z
ero
V
oltage
S
wit
ching
Normally closed (Form B) for DC Output only
option avaialble.
(AC SSR)
Normally Closed (-B)
Available (DC Output)
MODEL NUMBER
MP
240D3-MS11
MP240D4-MS11
(1)ꢀ
A
C
OU
T
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
Operating Voltage Range (47-63 Hz) [Vrms]
24-280
.02-3
600
24-280
.02-4
600
Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
90
130
1.6
1.6
2
2
Maximum I t for Fusing, (8.3 msec.) [A sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] (2ꢀ)
Max. Turn-On Time
36
72
5.0
5.0
200
200
1/2 Cycle
1/2 Cycle
0.5
1/2 Cycle
1/2 Cycle
0.5
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
ꢀ
ꢀ
D
C
OU
T
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
(1)ꢀ
M
PD
CD
3
-MS11 (3)
M
PD
CD
3-B-MS11 (3)
Operating Voltage Range [Vdc]
3-60
3-60
Load Current Range [Adc]
0.02-3.0
5.0
0.02-3.0
5.0
Max. Over Current (non-repetative) 1sec [A]
Max. On-State Voltage Drop @ Rated Current [Vdc]
1.5
1.5
100
100
1.0
Max. Turn-On time (T
Max. Turn-Off time (T
+ Trise ) [µs]
+ Tfall ) [µs]
100
delay
delay
100
Max. Off-State Leakage Current @ Rated Voltage [mA]
SPE
1.0
IN
P
U
T
CIFICATIONS (1)ꢀ
AC/DC Output
DC Output (-B)
Control Voltage Range [Vdc]
Must Turn-On Voltage [Vdc]
Must Turn-Off Voltage [Vdc]
3-32
3-32
3.0
1.0
1.0
3.0
Typical Input Current @ 5Vdc [mA]
Nominal Input Impedance [Ohms]
2.6
2.6
1500
1500
©2008 CRYDOM Inc, Specifications subject to change without notice.
G
E N E R A L N O T E S
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard
For recommended applications and more information contact:
RS-343, paragraph 13.11.1
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
3)ꢀInductive loads should be diode suppressed.
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: sales-europe@crydom.com, tech-europe@crydom.com
GERMANY: +49 (0)180 3000 506
SERIES MP-MS11
Rev. 180608
PAGE 1 OF 4