NOTES:
C
REVISION W
1.
REPRESENTS A CRITICAL DIMENSION.
MMSSX-XX-XXX-X-XX.XX-X-X-XXX
FEP CABLE OPTION
2. BURR ALLOWANCE: .003[0.08] MAX.
3. PARTS TO BE MOLDED TO POSITION.
OPTION
SINGLE
4. MINIMUM PULLOUT FORCE: 5 lbs [22.24 N].
-T: FEP INSULATION
DO NOT
SCALE FROM
THIS PRINT
5. CONTACT MUST BE INSERTED UNTIL RETENTION FEATURE LOCKS
INTO PLACE.
(LEAVE BLANK FOR
W
W
-M: METAL LATCH (USE IPD1-XX-S-X-M)
C
STANDARD PVC INSULATION)
6. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING
HI-POT TEST @ 1000 VOLTS DC. AFTER FINAL ELECTRICAL TEST,
LABEL EACH ASSEMBLY WITH 1 LABEL-ET.
(LEAVE BLANK FOR PLASTIC)
DOUBLE
7. TINNED COPPER WIRE CONTAINS LEAD.
[MUST BE USED ON -D END OPTION ONLY
& APPLIES TO END 2 HOUSING]
-LUS: PLASTIC LATCH UP, STRAIGHT
-LDS: PLASTIC LATCH DOWN, STRAIGHT
-MUS: METAL LATCH UP, STRAIGHT
-MDS: METAL LATCH DOWN, STRAIGHT
No OF POSITIONS
-02 THRU -25
8. PARTS ARE TO BE LAYER PACKAGED.
9. CONTACTS OFFSET FOR POLARIZATION.
C
10. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP
DIMENSIONS, TOLERANCES, TOOLING AND ITS REQUIREMENTS.
11. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL BE ±.125[3.18].
FOR OTHER LENGTHS, TOLERANCES SHALL BE ± 2%.
WIRE GAUGE (AWG)
PVC:-20, -22, -24, -26, -28, -30
FEP:-20, -24, -28, 30
OPTION
-K: KEYED POLARIZATION
(USE IPD1-XX-S-K)
COLOR CODE
(No OF POS x .100[2.54])
(SEE FIG 3, SHEET 2)
(LEAVE BLANK FOR NO POLARIZATION;
AVAILABLE TO EXISTING CUSTOMERS ONLY)
C (SEE TABLE 2)
+ .055[1.40] REF
(LEAVE BLANK FOR
02 01
STANDARD BLACK CABLE)
(NOT AVAILABLE WITH FEP OPTION)
.300 7.62
REF
.200 5.08
REF
END OPTION
-S: SINGLE END
-D: DOUBLE END(MUST CHOOSE XUS OR XDS OPTIONS.)
C
L
PLATING SPECIFICATION
-F: FLASH SELECTIVE (USE C-179-XX-F)
-L: LIGHT SELECTIVE (USE C-179-XX-L)
-S: SELECTIVE (USE C-179-XX-S)
ASSEMBLED LENGTH
.010 0.25 REF
(SEE NOTE 9)
SPECIFY IN INCHES [USE DWCX-XX-XX]
(SINGLE END: 03.00[76.2] INCH MINIMUM,
DOUBLE END: 03.25[82.6] INCH MINIMUM)
IPD1-XX-S
"A"
.505 12.83
REF
C-179-XX-X
.285 7.24
REF
C
XX.XX
(SEE NOTE 11)
C
DWC-XX-10-300
XX.XX
(SEE NOTE 11)
FIG 1
MMSS-05-22-X-XX.XX-S SHOWN
"A"
SECTION "A"-"A"
FIG 2
MMSS-05-22-X-XX.XX-D-LUS SHOWN
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
.XX: .01 [0.3]
2
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.XXX: .005 [0.13]
.XXXX: .0020 [0.051]
SHEET SCALE: 1.5:1
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
.100[2.54] SOCKET DISCREET CABLE ASSEMBLY
HOUSING: NYLON 6/6, COLOR: WHITE
CONTACT: PHOS BRONZE
DWG. NO.
CABLE; INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
MMSSX-XX-XXX-X-XX.XX-X-X-XXX
BY:
DEAN P
05/03/2005 SHEET 1 OF 3
F:\DWG\MISC\MKTG\MMSSX-XX-XXX-X-XX.XX-X-X-XXX-MKT.SLDDRW