NOTES:
C
REVISION AF
1.
REPRESENTS A CRITICAL DIMENSION.
MMSSX-XX-XXX-X-XX.XX-X-X-XXX
FEP CABLE OPTION
2. BURR ALLOWANCE: .003[0.08] MAX.
3. PARTS TO BE MOLDED TO POSITION.
OPTION
SINGLE
4. MINIMUM PULLOUT FORCE: 5 lbs [22.24 N].
-T: FEP INSULATION
DO NOT
SCALE FROM
THIS PRINT
5. CONTACT MUST BE INSERTED UNTIL RETENTION FEATURE LOCKS
INTO PLACE.
(LEAVE BLANK FOR
-M: METAL LATCH (USE IPD1-XX-S-X-M)
C
STANDARD PVC INSULATION)
(SEE NOTE 13)
6. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING
HI-POT TEST @ 1000 VOLTS DC. AFTER FINAL ELECTRICAL TEST,
LABEL EACH ASSEMBLY WITH 1 ET STAMP ON THE BODY.
7. TINNED COPPER WIRE IS ROHS COMPLIANT.
8. PARTS ARE TO BE LAYER PACKAGED.
(LEAVE BLANK FOR PLASTIC)
DOUBLE
[MUST BE USED ON -D END OPTION ONLY
& APPLIES TO END 2 HOUSING]
-LUS: PLASTIC LATCH UP, STRAIGHT
-LDS: PLASTIC LATCH DOWN, STRAIGHT
-MUS: METAL LATCH UP, STRAIGHT
-MDS: METAL LATCH DOWN, STRAIGHT
No OF POSITIONS
-02 THRU -25
9. CONTACTS OFFSET FOR POLARIZATION.
10. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP
DIMENSIONS, TOLERANCES, TOOLING AND ITS REQUIREMENTS.
11. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL BE ±.125[3.18].
FOR OTHER LENGTHS, TOLERANCES SHALL BE ± 2%.
12. GOLD PLATING IS NOT REQUIRED ON THE OUTSIDE OF THE CONTACT
BOX OR ON THE SIDE WITH THE RETENTION LANCE.
13. ASSEMBLIES USING THE FEP OPTION ARE
WIRE GAUGE (AWG)
PVC:-20, -22, -24, -26, -28, -30
FEP:-20, -24, -28, 30
OPTION
-K: KEYED POLARIZATION
(USE IPD1-XX-S-K)
COLOR CODE
FOR CRIMP APPLICATIONS ONLY.
(SEE FIG 3, SHEET 2)
C (SEE TABLE 2)
(No OF POS x .100[2.54])
(LEAVE BLANK FOR NO POLARIZATION;
AVAILABLE TO EXISTING CUSTOMERS ONLY)
(LEAVE BLANK FOR
+ .055[1.40] REF
STANDARD BLACK CABLE)
(NOT AVAILABLE WITH FEP OPTION)
02 01
END OPTION
-S: SINGLE END
-D: DOUBLE END(MUST CHOOSE XUS OR XDS OPTIONS.)
PLATING SPECIFICATION
.300 7.62
REF
.200 5.08
REF
-F: FLASH SELECTIVE (USE C-179-XX-F)
-L: LIGHT SELECTIVE (USE C-179-XX-L)
-S: SELECTIVE (USE C-179-XX-S)
C
L
ASSEMBLED LENGTH
SPECIFY IN INCHES [USE DWCX-XX-XX]
(SINGLE END: 03.00[76.2] INCH MINIMUM,
DOUBLE END: 03.25[82.6] INCH MINIMUM)
.010 0.25 REF
(SEE NOTE 9)
IPD1-XX-S
"A"
.505 12.83
REF
C-179-XX-X
.285 7.24
REF
C
XX.XX
(SEE NOTE 11)
DWC-XX-10-300
C
XX.XX
(SEE NOTE 11)
FIG 1
"A"
SECTION "A"-"A"
MMSS-05-22-X-XX.XX-S SHOWN
FIG 2
MMSS-05-22-X-XX.XX-D-LUS SHOWN
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
2
.XX: .01 [0.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.XXX: .005 [0.13]
.XXXX: .0020 [0.051]
SHEET SCALE: 1.5:1
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
.100[2.54] SOCKET DISCREET CABLE ASSEMBLY
HOUSING: NYLON 6/6, COLOR: WHITE
CONTACT: PHOS BRONZE
DWG. NO.
CABLE; INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
MMSSX-XX-XXX-X-XX.XX-X-X-XXX
BY:
DEAN P
05/03/2005 SHEET 1 OF 3
F:\DWG\MISC\MKTG\MMSSX-XX-XXX-X-XX.XX-X-X-XXX-MKT.SLDDRW