ML200MHISeries
Compact SMT, 2W
Medical Approved
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 2W Output Power
Conditions
Min.
4.5
Typ.
5.0
Max.
5.5
Units
5 VDC Input
• 4 kVAC rms Isolation
• Reinforced Insulation
• Low Leakage Current
• Compact SMT Case
• Single & Dual Outputs
• 2.0 MH MTBF
Input Voltage Range
12 VDC Input 10.8
24 VDC Input 21.6
Internal Capacitor
12.0
24.0
13.2
26.4
VDC
Input Filter
Reverse Polarity Input Current
Leakage Current
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz), See Note 2
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
0.3
2.0
A
µA
Conditions
Min.
Typ.
2.0
0.1
1.2
Max.
4.0
1.0
Units
%
%
• Industry Standard Pin-Out
• EN 60950 Approved
• EN 60601 Approved
Dual Outputs, Balanced Loads
Vin = Min to Max
1.5
%
See Model Selection Guide
100
Over Line, Load & Temp.
150
200
15
mV P - P
mV P - P
mV rms
%/°C
0.01
0.02
Momentary (0.5 Sec.)
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC rms
VPk
VAC
G⍀
Isolation Voltage, Rated
Isolation Test Voltage
Reinforced Insulation Working Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
60 Seconds 4,000
Flash Tested For 1 Sec 6,000
300
500 VDC
100 kHz, 1V
10
15
80
20
100
pF
kHz
50
Parameter
Conditions
Min.
-25
Typ.
Max.
+80
+90
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-50
+125
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
Weight
0.94 x 0.54 x 0.35 Inches (24.0 x 13.7 x 9.00 mm)
Non-Conductive Black Plastic (UL94-V0)
0.14 Oz (3.75g)
MicroPower Direct
292 Page Street
Suite D
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
Stoughton, MA 02072
USA
MTBF
Safety Approvals
Moisture Sensitivity Level
Absolute Maximum Ratings
Parameter
MIL HDBK 217F, 25°C, Gnd Benign
2.0
MHours
UL 60601, UL 60950, EN 60601, EN 60950
IPC/JEDEC J-STD-020C Level 2
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Typ.
Max.
9.0
18.0
30.0
260
650
Units
5 VDC Input -0.7
12 VDC Input -0.7
24 VDC Input -0.7
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
°C
mW