ML12509
ML12511
ML12513
MECL PLL Components
Dual Modulus Prescaler
Legacy Device: Motorola 12509, 12511, 12513
These devices are two–modulus prescalers which will divide by
5 and 6, 8 and 9, respectively. A MECL–to–MTTL translator is
provided to interface directly with the Motorola MC12014
Counter Control Logic. In addition, there is a buffered clock input
and MECL bias voltage source.
16
1
CERDIP 16 = E
CERAMIC PACKAGE
CASE 620
• ML12509 480 MHz (÷5/6), ML12511 550 MHz (÷8/9),
ML12513 550 MHz (÷10/11)
• MECL to MTTL Translator on Chip
• MECL and MTTL Enable Inputs
• 5.0 or –5.2 V Operation*
CROSS REFERENCE/ORDERING INFORMATION
PACKAGE
MOTOROLA
LANSDALE
CERDIP 16
CERDIP 16
CERDIP 16
12509/BEA
12511/BEA
12513/BEA
ML12509/BEA
ML12511/BEA
ML12513/BEA
• Buffered Clock Input — Series Input RC Typ, 20 Ω and 4.0 pF
• VBB Reference Voltage
• 310 mW (Typ)
PIN CONNECTIONS
* When using a 5.0 V supply, apply 5.0 V to Pin 1 (V
),
CCO
V
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
CC
Clock
CCO
Pin 6 (MTTL V ), Pin 16 (V ), and ground Pin 8
CC CC
Q
(V ). When using –5.2 V supply, ground Pin 1 (V
),
Pin 6 (MTTL V ), and Pin 16 (V ) and apply –5.2 V to
EE CCO
Q
( – )
V
BB
CC
CC
E1 MECL
E2 MECL
E3 MECL
Pin 8 (V ). If the translator is not required, Pin 6 may be
EE
( + )
left open to conserve DC power drain.
MTTL V
CC
E4 MECL
E5 MECL
MTTL Output
V
EE
MAXIMUM RATINGS
(Top View)
Characteristic
(Ratings above which device life may be impaired)
Power Supply Voltage
Symbol
Rating
Unit
V
EE
–8.0
Vdc
Vdc
(V = 0)
CC
Input Voltage
(V = 0)
V
in
0 to V
EE
CC
Output Source Current
Continuous
I
O
mAdc
50
Surge
100
Storage Temperature Range
T
stg
–65 to 175
°C
(Recommended Maximum Ratings above which performance may be
degraded)
Operating Temperature Range
T
A
–55 to 125
°C
DC Fan–Out (Note 1)
(Gates and Flip–Flops)
n
70
—
NOTES: 1. AC fan–out is limited by desired system performance.
Page 1 of 12
www.lansdale.com
Issue 0