MI600ERWSeries
2:1 Input, 6W,
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 6W Output Power
Conditions
12 VDC Input
Min.
9.0
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
9.0
18.0
36.0
Units
Input Voltage Range
Input Start Voltage
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
48 VDC Input
VDC
• 2:1 Input Voltage Range
• Miniature 1” x 1” Case
• 1,500 VDC Isolation
• 24 Standard Models
• Single & Dual Outputs
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Chassis Mount Option
• DIN Rail Option
VDC
Input Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Cross Regulation
Ripple (20 MHz)
Pi () Filter
Conditions
Min.
Typ.
1.0
0.5
0.2
0.5
Max.
2.0
1.5
0.5
1.0
5.0
25
Units
%
%
%
%
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 5% to 100%
See Note 1
%
See Note 2
See Note 2
15
50
300
3.0
mV P - P
mV P - P
µSec
%
%/°C
%VOUT
Noise (20 MHz)
75
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Over Voltage Protection
Output Short Circuit
General
500
5.0
0.03
140
25% Load Step Change
110
120
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
1,000
300
Standard
Level
Radiated Emissions
Conducted Emissions
ESD
See Note 4
See Note 4
EN 55022
EN 55022
Class A
Class A
Criteria B; 4 kV Contact
Criteria A; 10V/m
Criteria B; 2 kV
Criteria B; 4 kV
Criteria B; 2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
RS
See Note 5
See Note 5
See Note 6
EFT
Surge
CS
Voltage Dips
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+85
+105
+125
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-55
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
Weight
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)
Aluminum (UL94-V0)
0.46 Oz (15g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Typ.
Max.
Units
MHours
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
25.0
50.0
100.0
300
Units
VDC
°C
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com