5秒后页面跳转
MHL0512DF/ES PDF预览

MHL0512DF/ES

更新时间: 2024-11-23 03:49:23
品牌 Logo 应用领域
CRANE 转换器模拟IC信号电路输出元件输入元件局域网
页数 文件大小 规格书
7页 97K
描述
DC/DC CONVERTERS 5 VOLT INPUT

MHL0512DF/ES 技术参数

生命周期:Obsolete包装说明:,
Reach Compliance Code:unknownECCN代码:EAR99
风险等级:5.77其他特性:ADDITIONAL -12V OUTPUT AVAILABLE
模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE效率(主输出):78%
最大输入电压:8 V最小输入电压:4 V
标称输入电压:5 VJESD-30 代码:R-MDFM-P10
最大电网调整率:0.1%最大负载调整率:0.5%
功能数量:1输出次数:2
端子数量:10最高工作温度:85 °C
最低工作温度:-55 °C最大输出电压:12.12 V
最小输出电压:11.88 V标称输出电压:12 V
封装主体材料:METAL封装形状:RECTANGULAR
封装形式:FLANGE MOUNT保护:CURRENT
认证状态:Not Qualified表面贴装:NO
技术:HYBRID温度等级:OTHER
端子形式:PIN/PEG端子位置:DUAL
最大总功率输出:15 W微调/可调输出:NO
Base Number Matches:1

MHL0512DF/ES 数据手册

 浏览型号MHL0512DF/ES的Datasheet PDF文件第2页浏览型号MHL0512DF/ES的Datasheet PDF文件第3页浏览型号MHL0512DF/ES的Datasheet PDF文件第4页浏览型号MHL0512DF/ES的Datasheet PDF文件第5页浏览型号MHL0512DF/ES的Datasheet PDF文件第6页浏览型号MHL0512DF/ES的Datasheet PDF文件第7页 
FEATURES  
• –55°C to +85°C operation  
MHL SERIES  
15 WATT  
DC/DC CONVERTERS  
5 VOLT NPUT  
• 4 to 8 VDC input  
• Fully isolated  
I
• Opto-coupler feedback  
• Fixed frequency, 210 kHz typ.  
• Inhibit function  
MODELS  
VDC OUTPUT  
• Indefinite short circuit protection  
• Up to 80% efficiency  
DUAL  
±12  
±15  
Size (max.): Non-flanged, case F4  
1.950 x 1.350 x 0.505 inches (49.53 x 34.29 x 12.83 mm)  
Flanged, case J5  
2.720 x 1.350 x 0.505 inches (69.09 x 34.29 x 12.83 mm)  
See Section B8, cases F4 and J5, for dimensions.  
57 grams typical  
Weight:  
Screening: Standard or ES. See Section C2 for screening options, see Section  
A5 for ordering information.  
DESCRIPTION  
The efficiency is high over the entire input voltage range and from  
approximately 25% of full load to full load. This feature makes the  
converters ideal for either battery or aircraft power applications.  
The MHL Series™ of DC/DC converters offers either ±12 or ±15 volt  
outputs in a single package. MHL converters offer the high efficiency  
and wide input range of switching regulators with excellent load and  
line regulation. Input and output grounds are isolated from one  
another and from case ground. No external components are  
required for operation. The units are built using thick-film hybrid  
technology and are sealed in metal packages for military, aero-  
space, and other high-reliability applications. Unscreened models  
are sealed with solder and are guaranteed to pass a gross leak test  
An inhibit function is provided to allow power shut-down and start-  
up from a logic input. An open circuit on the inhibit terminal produces  
normal operation, and a low level disables the converter. Input  
current in the inhibit mode is typically 20 mA. The converter features  
a “soft-start” function which provides a controlled 20 millisecond  
turn-on upon application of input power or inhibit release.  
-3  
(maximum leak rate of 1 x 10 atm.-cc/sec). Environmentally  
screened models (/ES) are hermetically sealed with solder and will  
pass a fine leak and gross leak test as described in Section C2.  
An input filter is incorporated in the unit to reduce input reflected  
ripple current. Both outputs are indefinitely protected against short  
circuits to ground or to one another by automatic current limiting  
circuitry. This feature adjusts the converter’s output current, indefi-  
nitely maintaining it below approximately 125% of the rated  
maximum during a full short circuit condition.  
The MHL converters employ pulse-width modulated switching regu-  
lator techniques in the forward mode, with  
a nominal clock  
frequency of 210 kHz. Isolation is achieved through the use of a  
transformer in the forward power circuit and an opto-coupler in the  
feedback/control loop. The full load output power (15 watts) is avail-  
able over the input range of 4 to 8 VDC. Up to 14.3 watts can be  
obtained from a single output up to a combined load of 15 watts.  
The MHL Series of converters is rated to operate at full load at a  
case temperature of 85°C, with the output power derated linearly to  
zero at 115°C (0.5W/°C). Because of the unit’s high efficiency, heat  
sinking requirements are minimized, but due consideration should  
be given to removing self-generated heat when operating the device  
at maximum ratings. To increase dissipation, heat conducting mate-  
rial (PCB, copper sheet, heat sink, or Interpoint’s TMP accessory)  
should be brought into contact with the converter’s baseplate.  
Typical Performance Curve  
84  
V
IN=4 V  
V
IN=5 V  
82  
80  
78  
76  
74  
72  
70  
When the MHL is used in applications requiring full-power operation  
for extended periods of time, or in shock and vibration environ-  
ments, it is highly recommended that the flange-mount case option  
be used. This option provides improved thermal transfer capabilities  
as well as mechanically secure mounting configuration.  
V
IN=8 V  
2
4
6
8
10  
12  
14  
16  
18  
OUTPUT POWER (WATTS)  
MHL0515D Efficiency  
FIGURE 1  
B4-17  

与MHL0512DF/ES相关器件

型号 品牌 获取价格 描述 数据表
MHL0512SF/ES CRANE

获取价格

DC/DC CONVERTERS 5 VOLT INPUT
MHL0515D CRANE

获取价格

Analog Circuit, Hybrid, MDIP10,
MHL0515D/ES CRANE

获取价格

Analog Circuit, Hybrid, MDIP10,
MHL0515DF/ES CRANE

获取价格

DC/DC CONVERTERS 5 VOLT INPUT
MHL0515SF/ES CRANE

获取价格

DC/DC CONVERTERS 5 VOLT INPUT
MHL11740K MICROSEMI

获取价格

Adjustable Positive Standard Regulator, PSSO3, TO-257, 3 PIN
MHL11740K-1 MICROSEMI

获取价格

Adjustable Positive Standard Regulator
MHL11740K-1A MICROSEMI

获取价格

Adjustable Positive Standard Regulator,
MHL11740K-3 MICROSEMI

获取价格

Adjustable Positive Standard Regulator
MHL11740K-4 MICROSEMI

获取价格

Adjustable Positive Standard Regulator