描述
DC/DC CONVERTERS 28 VOLT INPUT

MGH2805DZ/ES 技术参数

生命周期:Contact Manufacturer包装说明:,
Reach Compliance Code:compliantECCN代码:EAR99
风险等级:5.56模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
最大输入电压:50 V最小输入电压:12 V
标称输入电压:28 VJESD-30 代码:R-MDMA-G18
JESD-609代码:e4功能数量:1
输出次数:1端子数量:18
最高工作温度:125 °C最低工作温度:-55 °C
最大输出电压:5.2 V最小输出电压:4.8 V
标称输出电压:5 V封装主体材料:METAL
封装形状:RECTANGULAR封装形式:MICROELECTRONIC ASSEMBLY
认证状态:Not Qualified表面贴装:YES
技术:HYBRID温度等级:MILITARY
端子面层:GOLD端子形式:GULL WING
端子位置:DUAL最大总功率输出:1.5 W
微调/可调输出:NOBase Number Matches:1

MGH2805DZ/ES 数据手册

 浏览型号MGH2805DZ/ES的Datasheet PDF文件第2页浏览型号MGH2805DZ/ES的Datasheet PDF文件第3页浏览型号MGH2805DZ/ES的Datasheet PDF文件第4页浏览型号MGH2805DZ/ES的Datasheet PDF文件第5页浏览型号MGH2805DZ/ES的Datasheet PDF文件第6页浏览型号MGH2805DZ/ES的Datasheet PDF文件第7页 
FEATURES  
• –55° to +125°C operation  
MGH SERIES  
1.5 WATT  
DC/DC CONVERTERS  
28 VOLT NPUT  
• 12 to 50 VDC input  
• Fully Isolated  
I
• Magnetic feedback  
MODELS  
VDC OUTPUT  
• Fixed frequency 370 kHz typical  
Topology – Current Mode Flyback  
• 80 V for up to 120 ms transient protection  
(70 V for 15 V single and dual models)  
• Inhibit function  
SINGLE  
DUAL  
±5  
5
12  
15  
±12  
±15  
• Indefinite short circuit protection  
• Up to 79% efficiency  
Size (max.): 1.010 x 0.880 x 0.250 inches (25.65 x 22.35 x 6.35 mm)  
Shown with “Gull Wing” lead option, also available with straight  
leads. See Section B8, case B, for dimensions and options.  
12 grams maximum  
Weight:  
Screening: Standard, ES, or 883 (Class H). See Section C2 for  
screening options, see Section A5 for ordering information.  
DESCRIPTION  
The MGH Series™ of DC/DC converters delivers 1.5 watts of output  
power in a labor saving surface mount package. The wide input  
voltage range of 12 to 50 VDC accepts the varying voltages of mili-  
tary, aerospace, or space applications. Single output converters  
feature outputs of 5, 12, or 15 volts while dual output models feature  
outputs of ±5, ±12, or ±15 volts. Transient protection of 80 volts for  
up to 120 milliseconds exceeds the requirements of MIL-STD-704A  
for the 5 and 12 volt single and dual models. The 15 volt single and  
dual converters will withstand transients of up to 70 volts for up to  
120 milliseconds.  
PROTECTION FEATURES  
Undervoltage lockout prevents the MGH Series converters from  
operating below approximately 8 VDC input voltage to keep system  
current levels smooth, especially during initialization or re-start oper-  
ations. All models include a soft-start function to prevent large  
current draw and minimize overshoot. The MGH Series of  
converters also provide short circuit protection by limiting the current  
to approximately 125% of full load.  
MIL-STD-461  
Use Interpoint’s FMGA-461 EMI filter to pass the CE03 require-  
ments of MIL-STD-461C.  
CONVERTER DESIGN  
MGH Series DC/DC converters incorporate a continuous flyback  
topology with a constant switching frequency of approximately 370  
kHz. Output voltage regulation is accomplished on the primary side  
using current-mode pulse width modulation (PWM). Regulation is  
affected by the output load; refer to the specifications tables for  
more information.  
SURFACE MOUNT PACKAGE  
MGH DC/DC converters can be surface mounted with pick-and-  
place equipment or manually. It is recommended that the case be  
attached with flexible epoxy adhesive or silicone which is thermally  
conductive (>1 watt /meter/°K).  
For dual output models, up to 80% of the total load may be on one  
output providing the other output carries a minimum of 20% of the  
total load. The dual models can be used at double the output voltage  
by connecting the load between positive and negative outputs,  
leaving the common unconnected. As an example the MGH2805D  
(5 volt dual output) can be used as a 10 VDC output.  
Internal components are soldered with SN96 (melting temperature  
221°C) to prevent damage during reflow. Maximum reflow tempera-  
ture for surface mounting the MGH converter is 220°C for a  
maximum of 30 seconds. SN60, 62, or 63 are the recommended  
types of solder. Hand soldering should not exceed 300°C for 10  
seconds per pin.  
INHIBIT FUNCTION  
The hermetically sealed metal cases are available in two different  
lead configurations. See Section B8, case B.  
When an open collector TTL logic low is applied to the inhibit  
terminal, pin 18, the converter shuts down and lowers the output  
voltage to near zero and input current to as low 2.3 mA. Leaving the  
terminal open or applying an open collector TTL logic high will  
enable the converter.  
B2-93  

与MGH2805DZ/ES相关器件

型号 品牌 获取价格 描述 数据表
MGH2805S CRANE

获取价格

DC/DC CONVERTERS 28 VOLT INPUT
MGH2805S CRANE

获取价格

MCH/MGH Single and Dual DC/DC Converters
MGH2805S/883 CRANE

获取价格

MCH/MGH Single and Dual DC/DC Converters
MGH2805SY/883 CRANE

获取价格

1-OUTPUT 1.5W DC-DC REG PWR SUPPLY MODULE
MGH2805SZ/883 CRANE

获取价格

Analog Circuit,
MGH2805SZ/ES CRANE

获取价格

DC/DC CONVERTERS 28 VOLT INPUT
MGH2812D CRANE

获取价格

MCH/MGH Single and Dual DC/DC Converters
MGH2812D/883 CRANE

获取价格

MCH/MGH Single and Dual DC/DC Converters
MGH2812DG CRANE

获取价格

暂无描述
MGH2812DZ/883 CRANE

获取价格

Analog Circuit,