MF-SERIES
Ⅵ Features
(1) Wide band: High attenuation.
Band wide: 150kHz ~ 30MHz, 2 stage filter
(2) Fast-on Terminals
(3) Compact, thin type package
Low profile metal case
10A type: 26mm
Ⅵ Safety standard
UL1283,
CSA Std. C22. 2 No. 8 (C-UL)
MF1216
VDE0565 Teil. 3
EN133200
5653
MF1210
E(NV133D200E0565 will expire on July 23, 2003.)
MF1206
Ⅵ Specifications
Model
(Note)
MF1206
MF1210
MF1216
16A
Item
1
2
3
4
Rated voltage (AC, DC)
Rated current (AC, DC)
250V
10A
6A
Test voltage (terminal to case, AC 1 minute)
Isolation resistance (terminal to case, 500VDC)
2500V (20mA) at 25°C, 70% RH
100MΩ min. at 25°C, 70% RH
0.5mA max.
125V, 60Hz
5
Leakage current
250V, 60Hz
1mA max.
6
7
8
9
DC resistance
140mΩ max.
50mΩ max.
34mΩ max.
Temperature rise
40°C max.
Operating temperature
Operating humidity
–25 ~ +85°C
30% ~ 95% RH (No dewdrop)
–40 ~ +85°C
10 Storage temperature
11 Storage humidity
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10 Hz (for one minute), Amplitude: 1,5 mm
X, Y and Z axes for 2 hours
12 Vibration
13 Safety standard
14 Weight
Approved by UL1283, CSA C22.2 No. 8 (C-UL), VDE0565 Teil 3 and EN133200 (VDE).
190g 220g 310g
(typ)
<
(Note) : Value at Ta 35°C. Refer to the derating curve shown below at Ta > 35°C.
=
Ⅵ Circuit
Ⅵ Derating
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
156