MODEL: MDP-FT
Lightning Surge Protectors for
Electronics Equipment M-RESTER
RELATED PRODUCTS
• Telemetering module (model: TMS)
• 300 bps modem (model: MOD2)
• 1200 bps modem (model: MOD3x)
• Voice/data modem (model: MOD4)
• 1200 bps modem (model: MOD5)
LIGHTNING SURGE PROTECTOR FOR TELEMETERING USE
(3.4 kHz)
Functions & Features
• Designed specifically to protect telemetering systems
utilizing leased circuit
GENERAL SPECIFICATIONS
Construction: Plug-in
• Applied to modems for computer using audio band signals
and to telemetering systems
Connection: M4 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
• Absorbs surges only without affecting instrumentation
signal
• No interruption of signal by unplugging the protector
element
INSTALLATION
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
23.5 (.93)
Weight:
120 g (0.26 lb), standard
Lot.NO
N1430B
100
(3.94)
JPAN
145 g (0.32 lb), with DIN rail mounting adapter
MADEIN
M•STER
MODEL
PERFORMANCE
Max. continuous operating voltage (Uc):
Line to line: ±1.2 V
80 (3.15)
mm (inch)
Line to earth: ±140 V
Voltage protection level (Up):
• @ 1 kV (100 A)
MODEL: MDP–FT[1]
Line to line: ±15 V
Line to earth: ±650 V
• @ 2 kV (1 kA)
ORDERING INFORMATION
• Code number: MDP-FT[1]
Specify a code from below for [1].
(e.g. MDP-FT/A33/Q)
Line to line: ±45 V
Line to earth: ±800 V
Response time:
• Specify the specification for option code /Q
(e.g. /C01)
Line to line: ≤ 4 nsec.
Line to earth: ≤ 20 nsec.
Leakage current @Uc:
Line to line: ≤ 20 μA
[1] OPTIONS (multiple selections)
DIN Rail Mounting Adapter
blank: Without
Line to earth: ≤ 10 μA
Max. discharge current (Imax): 5000 A (8 / 20 μs)
/A33: With adapter (model A-33)
Other Options
Nominal current (I ): 100 mA
N
Internal series resistance: ≤ 8 Ω ±20 % (including return)
Capacitance @ 1 MHz:
blank: none
/Q: Option other than the above (specify the specification)
Line to line: ≤ 500 pF
Line to earth: ≤ 100 pF
Surge protection: IEC 61643-21 Categories C1, C2, D1
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
MDP-FT SPECIFICATIONS
ES-8118 Rev.18 Page 1/4
http://www.m-system.co.jp/