Series
MD100SER
Low Cost, 1W SIP
Tightly Regulated
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 1W Output Power
• Tight Regulation
Conditions
Min.
Typ.
Max.
Units
5 VDC Input 4.75
5.0
5.25
12 VDC Input 11.40 12.0 12.60
15 VDC Input 14.25 15.0 15.75
24 VDC Input 22.80 24.0 25.20
Internal Capacitor
Input Voltage Range
VDC
• Miniature SIP Case
• 1,000 VDC Isolation
• 23 Single Output Models
• >3.5 MHour MTBF
• -40°C to +85°C Operation
• LOW COST
Input Filter
Output
Parameter
Conditions
For VIN Min to Max
Min.
Typ.
Max.
3.0
Units
%
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Temperature Coefficient
0.25
1.0
%
For IOUT = 10% to 100%
%
10
50
20
mV P - P
mV P - P
%/°C
See Note 2
75
0.03
12 VDC & 15 VDC Input Models
5 VDC and 24 VDC Input Models
Continuous (Autorecovery)
Momentary (1.0 Sec)
Output Short Circuit
General
Parameter
Conditions
Min.
Typ.
Max.
Units
VDC
M
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
60 Seconds 1,000
500 VDC 1,000
100 kHz, 1V
60
pF
100
kHz
Conditions
Min.
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
-40
-55
+25
+125
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
0.772 x 0.236 x 0.394 Inches (19.6 x 6.0 x 10.0 mm)
Non-Conductive Black Plastic (UL-94V0)
0.07 Oz (2.1g)
Case Material
Weight
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
3.5
MHours
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Max.
9.0
Units
VDC
°C
5 VDC Input -0.7
12 VDC Input -0.7
15 VDC Input -0.7
24 VDC Input -0.7
18.0
21.0
30.0
300
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com