Series
MD100DER
Dual Output, 1W SIP
Tightly Regulated
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 1W Output Power
• Tight Regulation
Conditions
Min.
Typ.
Max.
Units
5 VDC Input 4.75
5.0
5.25
Input Voltage Range
12 VDC Input 11.40 12.0 12.60
24 VDC Input 22.80 24.0 25.20
Internal Capacitor
VDC
• Miniature SIP Case
• 1,000 VDC Isolation
• 12 Dual Output Models
• >3.5 MHour MTBF
• -40°C to +85°C Operation
• LOW COST
Input Filter
Output
Parameter
Conditions
Min.
Typ.
Max.
3.0
Units
%
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Temperature Coefficient
For VIN Min to Max
0.25
1.0
%
For IOUT = 10% to 100%
See Note 2
%
10
50
20
mV P - P
mV P - P
%/°C
100
0.03
5 VDC Output Models
All Other Models
Continuous (Autorecovery)
Momentary (1.0 Sec)
Output Short Circuit
General
Parameter
Conditions
Min.
Typ.
Max.
Units
VDC
M
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
60 Seconds 1,000
500 VDC 1,000
100 kHz, 1V
60
pF
See Note 3
100
kHz
Conditions
Min.
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
-40
-55
+25
+125
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
1.083 x 0.374 x 0.472 Inches (27.5 x 9.5 x 12.0 mm)
Non-Conductive Black Plastic (UL-94V0)
0.173 Oz (5.2g)
Case Material
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
3.5
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
9.0
Units
VDC
°C
5 VDC Input -0.7
12 VDC Input -0.7
24 VDC Input -0.7
Input Voltage Surge (1 Sec)
18.0
30.0
300
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com