Key Features:
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 15W Output Power
• Wide 2:1 Input Range
• High Efficiency
Input
Parameter
Conditions
12 VDC Input
Min.
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
72.0
Units
9.0
Input Voltage Range
24 VDC Input 18.0
48 VDC Input 36.0
Internal Capacitors
VDC
• 1,500 VDC Isolation
• Single and Dual Outputs
• >1.12 MHour MTBF
• -40°C to +85°C Operation
Input Filter
Output
Parameter
Conditions
Min.
Typ.
1.0
Max.
Units
%
Output Voltage Accuracy
Line Regulation
VIN = Min to Max
Single Output
0.5
%
0.5
Load Regulation, IOUT = 0% to 100%
%
Dual Output, See Note 1
0.5
Ripple & Noise (20 MHz), See Note 2
Temperature Coefficient
Output Overload Protection
Output Short Circuit
General
100
0.02
140
mV P - P
%/°C
%IOUT
Continuous (Autorecovery)
Parameter
Conditions
Min.
Typ.
Max.
Units
VDC
VDC
M
Isolation Voltage
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Input/Output 3 Seconds 1,500
Case/Input or Output 1,000
500 VDC
1,000
1,000
125
100 kHz, 0.1V
pF
kHz
Conditions
Min.
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
+25
+100
+125
°C
-40
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
2.00 x 2.00 x 0.40 Inches (50.80 x 50.80 x 10.16 mm)
Metal Case, Epoxy Base (UL-94V0)
2.1 Oz (60.0g)
Case Material
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 1.121
MHours
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
Conditions
Min.
Max.
25.0
50.0
100.0
260
Units
VDC
°C
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (0.1 Sec)
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com