MB1500ERW
Low Cost, 1 x 2 Inch
15W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Conditions
12 VDC Input
Min.
9.0
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
9.0
Units
• 15W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Single & Dual Outputs
• Efficiency to 90%
Input Voltage Range
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
48 VDC Input
VDC
Input Start Voltage
17.8
35.8
VDC
VDC
mS
12 VDC Input
7.5
• Compact 1 x 2 Inch Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Low Cost
Under Voltage Shutdown
24 VDC Input 16.0
48 VDC Input 32.0
ꢀ (Pi) Filter
Input Filter
Start-Up Time
Output
Parameter
See Note 1
10
Conditions
Min.
Typ.
1.0
0.5
10
0.2
0.5
Max.
3.0
1.0
Units
%
Output Voltage Accuracy
Output Voltage Balance
Output Trim Range
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit, See Note 4
General
Dual Outputs, Balanced Loads
%
%
%
VIN = Min to Max
IOUT = 10% to 100%
See Note 2
0.5
1.0
5.0
%
See Note 3
70
150
0.02
100
mV P - P
%
%/°C
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
See Note 5
Typ.
Max.
Units
VDC
M
pF
kHz
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
1,000
300
Conditions
Min.
-40
Typ.
+25
Max.
+85
+105
+125
Units
°C
°C
Ambient
Case
-55
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
Weight
2.0 x 1.0 x 0.465 Inches (50.8 x 25.4 x 11.8 mm)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
0.99 Oz (28g)
Remote On/Off
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Conditions
Min.
2.5
0
Typ.
Max.
12.0
1.2
Units
VDC
VDC
mA
Unit On
Unit Off
Off Idle Current
Reliability Specifications
Parameter
See Note 6
See Note 6
1.0
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min.
Typ.
Max.
25.0
50.0
100.0
300
Units
VDC
°C
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com