MB-SERIES
Ⅵ Features
(1) Wide band: High attenuation.
Band wide: 150kHz ~ 30MHz, 2 stage filter
(2) Block terminal with cover type
Simple wire connection, high safety by cover
(3) Compact, low profile package
Low profile metal case, 10A type: 26mm
MB1236
MB1220
Ⅵ Safety standard
UL1283,
CSA Std. C22. 2 No. 8
VDE0565 Teil 3, Teil 3A2
EN133200
MB1216
5653
EN133200
(VDE0565 will expire on July 23, 2003.)
MB1210
MB1206
Ⅵ Specifications
Model
MB1206
6A
MB1210
10A
MB1216
MB1220
20A
MB1236
36A
Items
1
2
3
4
Ratedl voltage (AC, DC)
Rated current (AC, DC)
250V
16A
(Note 1)
Test voltage (terminal to case, AC 1 minute)
Isolation resistance (terminal to case, 500VDC)
2500V (20mA) at 25°C, 70% RH
100MΩ min. at 25°C, 70% RH
0.5mA max.
125V, 60Hz
5
Leakage current
250V, 60Hz
1mA max.
6
7
8
9
DC resistance
140mΩ max.
50mΩ max.
34mΩ max.
20mΩ max.
9mΩ max.
Temperature rise
40°C max.
Operating temperature
Operating humidity
–25 ~ +85°C
30% ~ 95% RH (No dewdrop)
–40 ~ +85°C
10 Storage temperature
11 Storage humidity
12 Vibration
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10Hz (for 1 minute), Amplitude: 1.5mm X, Y and Z axes for 2 hours each
Approved by UL1283, CSA C22.2 No. 8 (C-UL), VDE0565 Teil3, Teil3A2 and EN133200 (VDE)
13 Safety standard
14 Weight (typ)
190g
220g
310g
<
530g
660g
(Note) : Value at Ta 35°C. Refer to the derating curve shown below at Ta > 35°C.
=
Ⅵ Circuit
Ⅵ Derating
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
137