MB1000MHI
Medical Approved, 10W
Compact 1 x 2 Inch
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
Conditions
12 VDC Input
Min.
7.0
Typ.
8.0
15.0
33.0
Max.
9.0
18.0
36.0
8.5
Units
• 10W Output Power
• 4.2 kVAC rms Isolation
• Reinforced Insulation
• 10 µA Leakage Current Max
• Wide 2:1 Input Range
• Compact 1 x 2 In Case
• Single & Dual Outputs
• Meets EN55022
Input Start Voltage
24 VDC Input 13.0
48 VDC Input 30.0
12 VDC Input
24 VDC Input
48 VDC Input
VDC
Under Voltage Shutdown
16.0
34.0
VDC
Input Filter
(Pi) Filter (Complies with EN55022 Class A)
Leakage Current
Short Circuit Input Power
Output
240 VAC, 60 Hz
10
3,000
µA
mW
Parameter
Conditions
Min.
Typ.
Max.
1.0
2.0
Units
%
%
• 1.0 MH MTBF
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
• EN 60950 Approved
• EN 60601 Approved
Dual Output , Balanced Loads
VIN = Min to Max
0.5
0.3
0.5
%
IOUT = 15% to 100%
IOUT = 5% to 100%
5V/5.1V Output
0.5
0.6
75
100
150
300
3.0
1.0
1.2
100
150
Load Regulation
%
Ripple & Noise (20 MHz), See Note 1
mV P - P
All Other Outputs
Output Power Protection
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
120
%
µSec
%
600
5.0
0.05
25% Load Step Change
0.02
%/ºC
Continuous (Autorecovery)
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC rms
VPk
VAC
G⍀
Isolation Voltage, Rated
Isolation Test Voltage
Reinforced Insulation Working Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
60 Seconds 4,200
Flash Tested For 1 Sec 6,000
300
500 VDC
100 kHz, 1V
10
60
150
80
180
pF
kHz
120
Parameter
Conditions
Min.
-40
Typ.
Max.
+75
+95
Units
ºC
ºC
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-50
+125
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
2.00 x 1.00 x 0.47 Inches (50.8 x 25.4 x 12.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.86 Oz (24.5g)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
MHours
Safety Approvals
Absolute Maximum Ratings
Parameter
UL 60601, UL 60950, EN 60601, EN 60950
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Typ.
Max.
25.0
50.0
100.0
260
Units
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
ºC
mW
4,000
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com