MB1000MRWRI4
EN 60601 Approved
Compact, 2:1 Input, 10W
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• EN 60601 3RD Ed. Approved
• 10W Output Power
Input
Parameter
Conditions
12 VDC Input
Min.
7.0
Typ.
8.0
Max.
9.0
Units
• 4.2 kVrms Isolation
Input Start Voltage
24 VDC Input 13.0
48 VDC Input 30.0
12 VDC Input
15.0
33.0
18.0
36.0
8.5
VDC
• Reinforced Insulation
• 1 x MOPP & 2 x MOOP per
EN 60601-1 3RD Edition &
ANSI/AAMI ES 60601-1
• 10 µA Max Leakage Current
• Wide 2:1 Input Range
• Compact 1 x 2 In Case
• Single & Dual Outputs
• 1.0 MH MTBF
Under Voltage Shutdown
24 VDC Input
48 VDC Input
16.0
34.0
VDC
mW
Input Filter
Short Circuit Input Power
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
(Pi) Filter
3,000
Conditions
Min.
Typ.
Max.
1.0
Units
%
Dual Output , Balanced Loads
VIN = Min to Max
0.5
0.3
0.5
0.6
2.0
0.5
1.0
1.2
100
150
%
%
IOUT = 15% to 100%
IOUT = 5% to 100%
5V Output
Load Regulation
%
Ripple & Noise (20 MHz), See Note 2
mV P - P
All Other Outputs
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
120
150
300
3.0
%
µSec
%
600
5.0
0.05
25% Load Step Change
0.02
%/ºC
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 4,200
300 Vrms
Typ.
Max.
Units
Vrms
Isolation Voltage, Rated
Reinforced Insulation Working Voltage
Leakage Current
240 VAC, 60 Hz
500 VDC
10
µA
G⍀
pF
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
10
100 kHz, 1V
60
150
80
180
120
kHz
Parameter
Conditions
Min.
-40
Typ.
Max.
+75
+95
Units
ºC
ºC
Ambient
Case
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
-50
+125
ºC
Free Air Convection
RH, Non-condensing
95
4,000
%
m
Altitude
Physical
Case Size
See Mechanical Diagram (Page 3)
Case Material
Weight
Reliability Specifications
Parameter
Non-Conductive Black Plastic (UL94-V0)
0.86 Oz (24.5g)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
MHours
IEC/EN 60601-1, EN 60601-1 3RD Edition, 1xMOPP & 2xMOOP
ANSI/AAMI ES 60601-1 1xMOPP & 2xMOOP Recognition, (UL Certificate)
ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1
Safety Standards
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
25.0
50.0
100.0
260
Units
VDC
ºC
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com