NON-STOCK ITEM; SPECIAL ORDER ONLY
NOT FOR NEW DESIGNS
MAX-250, MAX-350, Multiple Output
FEATURES:
• Over 3 watt/in3 power density
• 80% overall efficiency
• Meets international safety agency requirements
• All outputs regulated ±1%
• High peak currents for motor starting
• System air or self-cooling options
• Ac automatic line selection option
• Available in 24, 28, or 48 Vdc input
Option C
OPTIONS:
Option “A”, Ac Auto-Range: Automatically selects proper ac
line voltage range to enable power operation at either 115 or 230
Vac without user intervention.
SPECIFICATIONS:
INPUT
Ac Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable.
See option “A” for automatic line selection. Internally fused for 10 A.
Inrush: Cold start ac current is less than 10 A at 115 Vac and
18 A at 230 Vac.
Option “C”, Cover: Limits contact with power supply interior.
Option “F”, Fan/Cover Assembly: Cover with integral ball-
bearing fan provides proper cooling to achieve full ratings at 50°C
ambient temperature.
Holdup Time: 16 ms minimum after removal of power, at
nominal line, full load.
Efficiency: 80% typical.
Option “P”, Ac Power Fail: Provides TTL “0” 5 ms before
output voltage goes out of regulation band upon loss of ac power.
VMEbus compatible, provides 48 mA sink current capability. Not
available if option “G” is selected.
Brownout Protection: Holds regulation to 85 Vac or 170 Vac.
OUTPUT
Adjustability: User adjustable ±5% minimum.
Line & Load Regulation: ±1% over ac input range and 0 to
100% load change. Output #1 requires minimum load of 10%.
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is
greater.
AC INPUT
FUNCTION
115 VAC
230 VAC
Open
CONNECTOR
0.187 Male Fastons
Barrier strip
Input Select Short
TB1-(L)
TB1-(N)
Line
Line 1
Line 2
Remote Sense (Output #1): Compensates for 250 mV total line
drop. Open sense lead protection.
Neutral
#6-32 screws
Temperature Coefficient: 0.02% per degree C.
Stability: 0.1% over 8 hours after 30 minutes warm-up.
Transient Response (Output #1): Output voltage returns to
within 1% in less than 500 µs for a 50% load change. Peak
transient does not exceed 5%.
Overload Protection: All outputs are protected against overload
and short circuit. Automatic recovery upon removal of fault.
Overvoltage Protection (Output #1): Protects load against
power supply induced overvoltage. Trip point is factory set so
that output voltage cannot exceed 136% of nominal.
Remote Inhibit: Contact closure to the negative sense line
drops output power to nominal zero.
TB1-(GND) Safety Ground Safety Ground 3/8" centers
DC INPUT
FUNCTION
MAX
Terminal marked +V
Terminal marked COM
TB2-3 (+)
CONNECTOR
Bus bars
Output #1
#10/32 screws
Output #2
Output #3
Output #4*
TB2-4 Rtn (Common)
TB2-5 (-)
Barrier strip
#6-32 Screws
3/8" centers
TB2-4 Rtn (Common)
TB2-1 (+)
Reverse Voltage: Protected against reverse voltage up to
supply current rating.
ENVIRONMENTAL
TB2-2 (-)
Thermal Protection: Shuts down power supply if overheated.
Automatic recovery.
Temperature Range: 0° to 50°C at full ratings. Derate to half
power at 70°C.
STATUS AND CONTROL
FUNCTION
LOCATION
NOTES
Output #1 Sense
CONNECTOR
AMP MTA type
Remote Sense
J1-1(+S)
Safety Agencies: Most models are approved to UL1950; CSA
22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/
EEC/93/68EEC (low voltage directive).
Conducted RFI: Meets FCC Part 15, Subpart J, Class A;
EN55022 Class B; CISPR 22 Class B.
J1-2 (S-)
Output #1 Sense Rtn #640456-4 pin
Ac Power Fail or J1-3 (PF)
Dc Power Good*
Reference to J1-2
header (locking)
Inhibit
J1-4 (H)
Short to J1-2
Cooling: 30 cfm required to achieve full ratings.
Output Isolation: Isolated from ground 50 Vdc.
*Rtn connected to common only if output is polarized in product selection chart
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com