MAU400 SERIES
DC/DC CONVERTER 1W, Reinforced Insulation, Medical Safety
FEATURES
►Small SIP Package
►Reinforced Insulation rated for 300VAC Working Voltage
►I/O–isolation 3000VACrms
►Industrial & Medical Safety Approval
►Operating Temp. Range -25°C to +85°C
►Low Coupling Capacity
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MAU400 series is a range of 1W DC/DC converter modules providing a high I/O-isolation voltage of 3000VAC in a small SIP-package. There
are 12 models available for 5VDC or 12VDC input voltage and single- or dual-output voltage.
This product offers an economical solution for many applications in industrial controls and Instrumentation, consumer electronics and everywhere where a
certified supplementary or reinforced insulation system is required to comply with relative safety standards.
Model Selection Guide
Model
Input
Voltage
(Range)
VDC
Output
Output Current
Input Current
Load
Max. capacitive
Load
Efficiency
(typ.)
Number
Voltage
Regulation
@Max. Load
@No Load
mA(typ.)
Max.
Min.
@Max. Load
VDC
5
mA
200
80
mA
4
mA(typ.)
303
291
295
303
267
287
126
121
123
126
108
117
% (max.)
µF
%
66
66
66
66
72
73
66
66
66
66
74
75
MAU401
MAU402
MAU403
MAU404
MAU405
MAU406
MAU411
MAU412
MAU413
MAU414
MAU415
MAU416
10
8
12
15
5
2
680
5
(4.5 ~ 5.5)
65
1
8
55
30
100
40
2
10
8
220#
680
12
15
5
1
35
1
8
200
80
4
10
8
12
15
5
2
12
65
1
8
(10.8 ~ 13.2)
100
40
2
10
8
12
15
1
220#
35
1
8
# For each output
Input Specifications
Parameter
Model
5V Input Models
Min.
Typ.
5
Max.
5.5
13.2
9
Unit
4.5
10.8
-0.7
-0.7
---
Input Voltage Range
12V Input Models
5V Input Models
12V Input Models
12
---
VDC
Input Surge Voltage (1 sec. max.)
---
29
Reverse Polarity Input Current
Internal Filter Type
---
0.3
A
All Models
LC Filter
Internal Power Dissipation
---
---
650
mW
Output Specifications
Parameter
Conditions
Min.
---
Typ.
1.0
0.1
1.2
Max.
3.0
Unit
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
---
1.0
%
---
1.5
%
Load Regulation
See Model Selection Guide
Ripple & Noise
max. 20MHz Bandwidth
---
---
100
150
mV P-P
Temperature Coefficient
Short Circuit Protection
0.01
0.02
%/℃
0.5 Second Max.
E-mail:sales@minmax.com.tw Tel:886-6-2923150