MAP80 AC-DC Series Data Sheet
Features
•
•
•
•
RoHS lead-solder-exemption compliant
Wide-range input for 110/220 VAC applications
CE marked to Low Voltage Directive
Input transient & ESD compliance to
EN61000-4-2/-3/-4
•
•
•
•
Meets EN55022, Class B limits
TTL compatible Power Fail Signal
Greater than 175,000 Hours MTBF
Metric and SAE mounting inserts
Description
Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power
operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each
mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections
or popular single-row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific
output voltage requirements.
Single Output Model Selection
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 3)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
MODEL
MAP80-1005
MAP80-1012
MAP80-1024
5V
12V/15V
24V/28V
4.5V to 5.6V
11.5V to 15.5V
23.0V to 29.0V
16A
7.5/6A (Note 2)
3.8/3.2A (Note 2)
18A
0.2%
0.2%
0.1%
1%
1%
0.5%
1.4%
1%
0.5%
5.0V to 5.1V
11.76V to 12.15V
23.8V to 24.2V
9.2/7.3A (Note 2)
4.6/3.9A (Note 2)
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Multiple Output Model Selection – 80W Continuous Output Power
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
+5V
+12V
-5V
-12V
+5V
+24V
-12V
+12V
+5V
+12V
-12V
+12V
+5V
+15V
-5V
-15V
+5V
+24V
-15V
+15V
4.8V to 5.5V
11.52V to 12.48V
Fixed
14A
4A
1A
1A
14A
2A
1A
1A
14A
4A
1A
16A
7A
1A
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.1V to 5.2V
11.9V to 12.1V
-4.8V to -5.4V
-11.5V to -12.5V
5.1V to 5.2V
24.0V to 24.1V
-11.5V to -12.5V
11.5V to 12.5V
5.1V to 5.2V
12.0V to 12.1V
-11.6V to -12.4V
11.6V to 12.4V
5.1V to 5.2V
14.6V to 15.1V
-4.8V to -5.4V
-14.4V to -15.5V
5.1V to 5.2V
MAP80-4000
Fixed
1A
4.8V to 5.5V
23.04V to 24.96V
Fixed
16A
3.5A
1A
1A
16A
7A
1A
1A
16A
6A
1A
MAP80-4001
MAP80-4002
MAP80-4003
MAP80-4004
Fixed
4.7V to 5.5V
11.52V to 12.48V
Fixed
Fixed
1A
4.8V to 5.5V
14.40V to 15.60V
Fixed
14A
3.5A
1A
1A
14A
2A
Fixed
1A
4.8V to 5.5V
23.04V to 24.96V
Fixed
16A
3.5A
1A
24.0V to 24.1V
-14.4V to -15.5V
14.4V to 15.5V
1A
1A
Fixed
1A
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MCD10144 Rev. 1.0, 02-Feb-10
Page 1 of 4
www.power-one.com