18W AC/DC Adapter
MA018-HASeries
FEATURES
Universal input Voltage: 90 - 264VAC, 50/60Hz
DoE Level VI efficiency
Over voltage, Over current, Short circuit protection
Fully enclosed plastic case
2 pole USA plug
Small wall-mounted type
RoHS
MA018-HA series is a small wall-mounted type adapter. This series features universal input voltage, low power consumption, high efficiency,
high reliability, and safer isolation, meets IEC/EN61000-4, CISPR22/EN55032 and UL60950. The entire series supplies different models with output
voltages range between 5V and 24V that can satisfy the demands for the various types of consumer electronic devices, telecommunication
devices, office and civil applications devices.
Electric Specifications
MA01805HA
5V
MA01809HA
9V
MA01812HA
12V
MA01815HA
15V
MA01818HA
18V
MA01824HA
24V
Model
DC Voltage
3.0A
2.0A
1.5A
1.2A
1.0A
0.75A
0-0.75A
18W
Rated current
Current range
Rated power
Voltage Accuracy
Line Regulation
Load Regulation
Output
0-3.0A
15W
0-2.0A
18W
0-1.5A
18W
0-1.2A
18W
0-1.0A
18W
±5%
±5%
±5%
±5%
±5%
±5%
±1%
±1%
±1%
±1%
±1%
±1%
±5%
±5%
±5%
±5%
±5%
±5%
120mVp-p max
120mVp-p max
120mVp-p max
150mVp-p max
180mVp-p max
240mVp-p max
Ripple &Noise*
Start-up time
3s@100-240VAC, full load
Hold-up time
10ms@115VAC, full load, 20ms@230VAC, full load
Rise time
30ms max
±10%
Overshoot/Undershoot
Transient response
Input voltage
Input frequency
Efficiency(Typ.)
Input current
Output voltage range ±5%, load 25%-50%, 50%-75%, slope:0.5A/us, frequency: 50Hz-10KHz
90-264VAC
47-63Hz
81.39%
85%
85%
85%
85%
85%
0.5A Max@100VAC, full load
Cold start: 40A/115VAC, 80A/230VAC
<0.1W
Input
Inrush current
No load power
Leakage current
0.25mA Max@240VAC
Over voltage
Rated output voltage 110%-150%
Protections Over current
Short circuit
Rated output current 110%-200%, self-recovery
Hiccup, Continuous, self-recovery
* Ripple and noise are measured by 20MHz bandwidth; at full load, 100-240VAC input, output terminated with a 0.1uF ceramic
capacitor and a 10uF electrolytic capacitor.
Note
General Specifications
Item
Operating Conditions
Min.
3000
100
Typ.
--
Max.
--
Unit
VAC
MΩ
Isolation Voltage
Insulation Resistance
Input-output, Test 1 minute, leakage current<5mA
Input-output, add 500Vdc test voltage
--
--
2017.12.28-A/2
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation