MODEL: M2XF2
Super-mini Signal Conditioners Mini-M Series
[2] OUTPUT
Current
Z1: Range 0 – 20 mA DC
Voltage
LINEARIZER
(PC programmable)
V1: Range -2.5 – +2.5 V DC
V2: Range -10 – +10 V DC
Functions & Features
• Accepting non-linear input and providing a linearized
output, proportional to the process variables
• 100-point calibration
(Configurator software is used to change output over the
described range of the selected suffix code. For changing
out of this range, set the Output Range Selectors inside the
unit before software adjustment.)
• PC programmable
Typical Applications
• V-notch weir
[3] POWER INPUT
• Gas analyzer
AC Power
• Irregular-shaped tank level input for volume calculation
• Square root extracting for DP transmitter
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(90 – 264 V for UL)
DC Power
23 (.91)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
M
od
el
76
(2.99)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
124
(4.88)
[4] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
mm (inch)
/CE: CE marking
/UL: UL approval, CE marking
Other Options
MODEL: M2XF2–[1][2]–[3][4]
blank: none
/Q: Option other than the above (specify the specification)
ORDERING INFORMATION
• Code number: M2XF2-[1][2]-[3][4]
Specify a code from below for each [1] through [4].
(e.g. M2XF2-S2Z1-R/CE/Q)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
• Input range (e.g. 1 – 5 V DC)
• Output range (e.g. 4 – 20 mA DC)
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
TERMINAL SCREW MATERIAL
/S01: Stainless steel (UL not available)
EX-FACTORY SETTING
[1] INPUT
/SET: Preset according to the Ordering Information Sheet
(No. ESU-5085)
Current
Z1: Range 0 – 50 mA DC (Input resistance 100 Ω)
Voltage
S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.)
S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)
(Configurator software is used to change input over the
described range of the selected suffix code. For changing
out of this range (between S1 and S2), set the Input Range
Selector on the side of unit before software adjustment.
For a current input, set the Selector to the same setting as
for S2 and use a receiving resistor.)
RELATED PRODUCTS
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
M2XF2 SPECIFICATIONS
ES-5085 Rev.12 Page 1/5
http://www.m-system.co.jp/