M2014S019-R 32.000000 数据手册

  
MHO+ Series  
14 pin DIP, 5.0 Volt, HCMOS/TTL, Clock Oscillator  
Features:  
•ꢀ Standard 14 DIP Package  
•ꢀ RoHS Compliant Version Available (-R)  
•ꢀ Tristate Option  
•ꢀ Wide Operating Temperature Range  
PARAMETER  
Symbol  
Min.  
Typ.  
Max.  
Units  
Condition/Notes  
Frequency Range  
Operating Temperature  
Storage Temperature  
Frequency Stability  
F
.732 kHz  
80  
MHz  
See Note 1  
T
T
A
S
(See ordering information)  
+125  
-55  
°C  
(See ordering information)  
F/F  
Aging  
1st Year  
Thereafter (per year)  
±3  
±2  
ppm  
ppm  
Input Voltage  
Input Current  
Vdd  
Idd  
4.5  
5.0  
5.5  
V
15  
25  
60  
mA  
mA  
mA  
.732 kHz to 2.999 MHz  
3.000 to 25.999 MHz  
26.000 to 80.000 MHz  
Output Type  
Load  
HCMOS/TTL  
See Note 2  
5 TTL or 50 pF  
10 TTL or 50 pF  
10 TTL or 15 pF  
.732 kHz to 2.999 MHz  
3.000 to 25.999 MHz  
26.000 to 80.000 MHz  
Pin Connections  
Symmetry (Duty Cycle)  
Logic “1” Level  
(See ordering information)  
See Note 3  
Voh  
Vol  
90% Vdd  
Vdd-0.5  
V
V
HCMOS Load  
TTL Load  
Logic “0” Level  
Output Current  
Rise/Fall Time  
10% Vdd  
0.5  
V
V
HCMOS Load  
TTL Load  
±8  
±16  
mA  
mA  
.732 kHz to 2.999 MHz  
3.000 to 80.000 MHz  
Tr/Tf  
See Note 4  
.732 kHz to 2.999 MHz  
3.000 to 80.000 MHz  
20  
10  
ns  
ns  
Tristate Function  
Start up Time  
Input Logic “1” or floating: output active  
Input Logic “0”: output to high-Z  
10  
12  
ms  
Available Symmetry  
Random Jitter  
Rj  
5
ps RMS  
1-Sigma  
Mechanical Shock  
Vibration  
MIL-STD-202, Method 213, C (100 g’s)  
MIL-STD-202, Method 201 & 204 (10 g’s from 10-2000 Hz)  
MIL-STD-883, Method 1010, B (-55°C to +125°C, 15 min dwell, 10 cycles)  
MIL-STD-202, Method 112  
Thermal Cycle  
Hermeticity  
Solderability  
Per EIAJ-STD-002  
Max Wave Soldering Conditions  
+260°C for 10 seconds  
1. Contact the factory for availability of higher frequencies.  
2. TTL load - see Load Circuit Diagram #1. HCMOS load - see Load Circuit Diagram #2.  
3. Symmetry is measured at 1.4 V with TTL load and at 50% Vdd with HCMOS load.  
4. Rise/fall times are frequency dependent and measured between 0.4 V and 2.4 V with TTL load, and between 10%  
Vdd and 90% Vdd with HCMOS Load.  
MtronPTI reserves the right to make changes to the product(s) and service(s) described herein without notice. No liability is assumed as a result of their use or application.  
Please see www.mtronpti.com for our complete offering and detailed datasheets. Contact us for your application specific requirements: MtronPTI 1-800-762-8800.  
Revision: 9-23-10