SPECIFICATION FOR HCMOS COMPATIBLE SMT OSCILLATOR
MtronPTI P/N M2002S273
Electrical Specifications:
Parameter
Frequency of Operation
Frequency Tolerance
Symbol
Min.
Typ.
25.000000
Max.
Units
MHz
Conditions
@ +23°C ± 3°C
FO
-25
+25
Includes initial calibration
tolerance, deviation over
operating temperature,
shock, vibration, supply,
load and aging.
Frequency Stability
-100
+100
ppm
F/F
Operating Temperature
Storage Temperature
Supply Voltage
Supply Current (1)
Supply Current (2)
Output Type
TA
TS
VDD
IDD1
IDD2
-55
-55
2.97
+125
+125
3.63
15
°C
°C
V
mA
mA
3.3
Output enabled
Output disabled
4
HCMOS Compatible
Output Load
Symmetry (duty cycle)
Logic “1” Level
Logic “0” Level
Rise/Fall Time
Tri-State Enable Logic
Tri-State Disable Logic
Enable Disable Time
15
60
pF
%
V
V
ns
V
TDC
VOH
VOL
TR/TF
VIH
40
90% VDD
Ref to ½ VDD
HCMOS load
HCMOS load
From 10% to 90% VDD
Pad 1
10% VDD
10
2.0
VIL
TSU
0.3
150
V
ns
Pad 1
Pad 1
Environmental & Mechanical Requirements:
Mechanical Shock
Vibration
Hermeticity
Per MIL-STD-202, Method 213, Condition C (100 g’s, 6 ms duration, ½ sinewave)
Per MIL-STD-202, Method 201 & 204 (10 g’s from 10-2000 Hz)
Per MIL-STD-202, Method 112 (1 x 10-8 atm cc/s of Helium)
Per EIAJ-STD-002
Solderability
Max. Soldering Conditions
Package Type
See solder profile, Figure 1
4- pad 5 X 7 X 1.9 mm leadless ceramic. (M2 type)
All parts that have completed the tests and screening requirements shall be marked with
a yellow color dot on the top cover of the device.
Part Marking
Testing/Screening Requirements:
All lots supplied to Hamilton Sunstrand shall have all Electrical Specifications as shown
above in this drawing verified at –55°C to +125°C. When tested, lot shall demonstrate a
percent defective of no greater that 0.5% (99.5% yield). A demonstrated reject rate of
greater that 0.5% will be sufficient cause for the lot to be rejected.
All parts from one lot shall be from one date code. Product shall be no older than one
year from the receiving date of the purchase order from Hamilton Sunstrand.
Special Product Testing
Date Code
1 of 2
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without written permission from MtronPTI.