MODEL: M1EAXV-1
Multi-output Super-mini Signal Conditioners
with Display M1E-1 Series
INPUT – Field-selectable
◆ DC Input
• Current input: 0 - 50 mA DC
• Voltage input: -1000 - +1000 mV DC
• Voltage input: -10 - +10 V DC
DC ALARM
(PC programmable, quad or octad alarm trip)
Functions & Features
[1] OUTPUT
• Provides relay outputs at preset DC input levels
• Octad or quad trip
A: 8 points; N.O. or make contact
B: 8 points; N.C. or break contact
C: 4 points; SPDT or transfer contact
• Front LCD display indicating values in scaled engineering
unit range is used to program the module
• Adjustable deadband (hysteresis)
• ON delay time selectable
POWER INPUT
DC Power
• Hi/Lo trip and energized/de-energized coil independently
selectable for each setpoint
R: 24 V DC
• Settable with front buttons
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• Enclosed relays
• Relays can be powered by 200 V AC and 100 V DC
• High-density mounting on DIN rail
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
Typical Applications
• Annunciator
• Various alarm applications
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
36 (1.42)
/C02: Polyurethane coating
/C03: Rubber coating
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-6031)
99
(3.90)
RELATED PRODUCTS
• Installation base (model: M1E-BS2)
125 (4.92)
• M1EA configurator software (model: M1EACFG)
Downloadable at M-System’s web site.
mm (inch)
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual (EM-5994) for the M1EA configurator for
applicable cable types.
Note: The !gure shows the combination
of the unit and the base.
MODEL: M1EAXV–1-[1]-R[2]
GENERAL SPECIFICATIONS
Construction: Plug-in
ORDERING INFORMATION
• Code number: M1EAXV-1-[1]-R[2]
Specify a code from below for each of [1] and [2].
(e.g. M1EAXV-1-A-R/Q)
Connection
• Connected to base with connector
• Base
• Specify the specification for option code /Q
(e.g. /C01/SET)
M2.6 screw terminals (torque: 0.5 N·m)
Applicable solderless terminal size (M3)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
Isolation:
NO. OF CHANNELS
1: 1 channel
• Output code A, B: Input to L1 or L2 alarm output to L3 or
M1EAXV-1 SPECIFICATIONS
ES-6031 Rev.2 Page 1/10
https://www.m-system.co.jp/