LX200 SERIES
Flexible single and muliple outputs
• 200W continuous , 300W pe ak output powe r
• Indus try s tandard footprint, low profile
• Conducte d nois e to me e t EN55022 clas s B
• AC and DC input voltage options in s ame package
• Efficie ncy up to 88%
• Optional powe r s haring/VME s ignals board
• Autoranging input option
The LX200 series offers 200 Watts of continuous output power in a low profile
industry standard footprint. With two single output options and a flexible
multiple output version, the series can address most power requirements as
standard. The design is specifically tailored to allow full flexibility and
modifications to meet customer applications can be implemented with relative
ease. The LX200 AC input series meets the safety requirements of EN60950,
VDE0805, UL1950 and CSA C22.2 No. 950. Input conducted noise levels meet
the requirements of FCC and EN55022 class B. LX200 series power supplies
are ideal for use in applications such as point-of-sale equipment, central and
public telecom power systems and network equipment.
[ 2 YEAR WARRANTY ]
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Voltage adjustability
Vout on singles
-8% /+16%
±20%
Conducted emissions
Radiated emissions
ESD air
EN55022, level A
+5V output on multiple
EN55022, level B
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
Remote sense
±10%
ESD contact
Surge
Line regulation
(LL to HL, FL)
Single outputs
±0.2%
±0.2%
Fast transients
Radiated immunity
Conducted immunity
Multiple: +5V output
Multiple: aux. outputs, Note 5 ±0.5%
Load regulation
Single outputs:
±0.2%
±1.0%
±4.0%
±2.0%
GENERAL SPECIFICATIONS
(20% to 100% FL)
Multiple: +5V output
Multiple: -5V output
Multiple: ±12V, 24V, Note 5
Hold-up time
Efficiency
110/230VAC
28ms
82% min.
Cross regulation
5A load step on main output
Auxiliary outputs, Note 5
1.0%
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Transient response
25% di/dt 1% max. dev., 1ms recov.
Switching frequency
Fixed
44kHz
Temperature coefficient Main/single output
±0.02% /°C
Multiple: auxiliary outputs ±0.04% /°C
Approvals and
standards
EN60950, VDE0805, UL1950
See Note 7
CSA C22.2 No. 950
Overvoltage protection Main/single output 130% ±10% Vout
Weight
1.3kg (46oz)
Output power limit
Multiples:
300W Pout
primary power limited
ENVIRONMENTAL SPECIFICATIONS
Singles:
current foldback
105% -120% Iout
Thermal performance
Operating
0°C to +70°C
–25°C to +85°C
Non-operating
Short circuit protection All outputs
Yes
0°C to +40°C ambient,
convection cooled
200W
INPUT SPECIFICATIONS
40°C to 70°C ambient, Derate linearly
convection cooled to 25% full load
Peak (0°C to 40°C, max. 10s) 300W
Input voltage range
See Note 3
LX200-46xx models, 175 to 264VAC
(230VAC version)
LX200-76xx models,
autorange version
Drop-out voltage
98 to 132VAC
190 to 264VAC
90VAC
Relative humidity
Altitude
Non-condensing
5% to 95% RH
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Input frequency
50Hz/60Hz
25A max.
Input surge current
Vibration
Operating, 5–50Hz
0.05mm pk-pk
Operating, 50–100Hz 0.025mm pk-pk
Safety ground
leakage current
115VAC, 60Hz
230VAC, 50Hz
1.6mA
2.5mA
Non-operating
100mm drop on
chassis face
Remote OFF
Logic 0 on ROF
PAGE 1