LW Series
Low Profile Triple Output
Features
26mm height
Outputs 2 and 3 isolated from output 1
Universal Input (85 - 265VAC)
Low Profile
Wattbox design on LWT
Key Market Segments & Applications
Specifications
Model
LWT15H
LWT30H
LWT50H
50
Max Output Power (typ)
Efficiency (Typ)
W
%
-
17
72
30
73
72
AC Input Voltage range
DC Input Voltage range
Input Current Typ (100/200VAC)
Inrush Current (110/200VAC)
Output 1 Voltage Adjustment
Output Voltage Accuracy
Temperature Coefficient
Line Regulation
85 - 265VAC (47 - 440Hz)
-
110 - 350VDC
0.4/0.22
110 - 330VDC
A
A
-
-
-
0.7/0.42
16/32
1.2/0/7
16/32
14/28
5V: 5 to 5.25V, 12V: 12 to 12.6V, 15V: 15V to 15.75V
Output 2 & 3 ±5%
Output 1 < 1%, Output 2 or 3, <2% at 0 - 60°C
-
1%
Load Regulation
-
2%
Ripple & Noise
-
Output 1: 100mV, Outputs 2 & 3: 150mV
Overcurrent Protection
Overvoltage Protection
-
V
>105%
Main output only: 5.75 - 6.75V, manual reset
Hold Up Time (Typ at 100VAC) ms
20
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
-
-
°C
-
-
-
Possible
LWT: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 80%, 60°C: 60%
-30 to +85°C
30 - 90% RH (Non condensing)
10 - 95% RH (Non condensing)
Convection
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
-
-
-
-
Input to Gnd 2kVAC Input to Output 3kVAC (20mA)
>100M at 25C & 70%RH, Output to Ground 500VDC
10-55Hz(1 min) <19.6m/s2 (1 hr)
196.1m/s2
Safety Agency Approvals
Conducted EMI
Weight (Typ)
-
-
g
IEC/UL/CSA/EN62368-1, 60950-1, CE Mark
VDE Class B, FCC Class B
220
300
400
Size (WxHxD)
Warranty
mm
-
Please refer to outline drawings
One Year
Note: See Installation Manual for full details, test methods of parameters and application notes