LTTH806SDF
HYPER-FAST
REVERSE VOLTAGE – 600Volts
GLASS PASSIVATED RECTIFIER
FORWARD CURRENT – 8.0 Ampere
FEATURES
ITO-220AC
•
•
Soft, Hyper fast switching capability
Specially suited for critical mode Power Factor
Corrections.
•
High reliability and efficiency
MECHANICAL DATA
•
•
Case: JEDEC ITOꢀ220AC
Case Material: Plastic material, UL flammability
classification 94Vꢀ0
•
•
•
Moisture Sensitivity: Level 1 per JꢀSTDꢀ020C
Terminals: Lead Free Plating
Polarity indicator: As marked on the body
•
•
•
Weight: 0.06 ounces, 1.7 grams
Component in accordance to RoHs 2002/95/EC
Maximum mounting torque = 0.5 N.m (5.1 Kgf.cm)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Parameter
Maximum Repetitive Peak Reverse Voltage
Average Rectified Output Current
Symbol
LTTH806SDF
Unit
V
600
8.0
V
RRM
See FIG.1
Tj=25°C
A
I
F
Symbol
Min.
Max.
Forward Voltage (1)
IF=8.0A
V
uA
1.8
3.4
V
F
Tj=25°C
Tj=125°C
15
200
Reverse Leakage Current
Reverse recovery time
VR=600V
I
R
IF= 0.5A
Irr= 0.25A
IR =1.0A
Tj=25°C
21
ns
t
rr
Symbol
Value
Unit
Thermal characteristics (
Non Repetitive Forward Surge Current
Operation and Storage temperature range
)
GBD
Tp=10ms
60
ꢀ55 to +175
2.7
A
I
FSM
°C
T , T
J
STG
JC
Typical thermal resistance_Junction to Case (2)
Typical thermal resistance_Junction to Lead (2)
°C/W
°C/W
Unit
RΘ
4.5
RΘ
JL
Symbol
Typical
Max.
Dynamic electrical characteristics (
)
GBD
IF=1A,
Reverse recovery time
dIF/dt=ꢀ200A/ꢁs,
VR=30V
Tj=25°C
12
18
ns
t
rr
Tj=25°C
Tj=125°C
Tj=25°C
Tj=125°C
1.8
5
60
220
2.2
6.0
ꢀꢀꢀ
I
RM
Reverse recovery current
IF=8 A,
dIF/dt=ꢀ200A/ꢁs,
V =200V
A
Q
Reverse recovery charges
Note :
nC
rr
ꢀꢀꢀ
REV. 9, Sep-2012, KTGC47
(1) 300us Pulse Width, 2% Duty Cycle.
(2) Thermal Resistance test performed in accordance with JESDꢀ51. RthjꢀL is measured at the PIN 2,
RthjꢀC is measured at the top centre of body.
(3) GBD means Guaranteed By Design, the spec is basically follow designer simulation.