描述
80 Watts

LPT81 数据手册

 浏览型号LPT81的Datasheet PDF文件第2页 
Total Power: 55-85 Watts  
Input Voltage: 85-264 VAC  
120-370 VDC  
80 Watts  
# of Outputs: Triple  
LPT80 Series  
Electrical Specs  
Input  
Input range  
85-264 VAC  
120-300 VDC  
Frequency  
Inrush current  
47-440 Hz  
<18 A peak @ 115 VAC;  
<36 A peak @ 230 VAC,  
cold start @ 25°C  
Input current  
Efficiency  
1.5 A max. (RMS) @ 115 VAC  
75% typical at full load  
FCC Class B conducted  
CISPR 22 Class B conducted  
EN55022 Class B conducted  
VDE 0878 PT3 Class B conducted  
EMI filter  
Safety ground  
leakage current  
<1 mA @ 50/60 Hz, 264 VAC input  
Special Features  
Output  
• Power Factor Correction  
Maximum power  
60 W for convection( LPT81, 55 W);  
85 W with 30 CFM forced air  
3.3V - 5.5V on outputs one  
(and two 1.8 V - 3.5 V for LPT81)  
20 ms @ 85 W load, 115 VAC  
nominal line  
Short circuit protection on all outputs.  
Case overload protected @ 145%  
above peak rating  
• EN61000-3-2 compliant  
• Universal input  
• 3” x 5” footprint  
• Remote sense on outputs 1 (& 2 for LPT81)  
• Power fail and remote inhibit  
• Wide range adjustable on outputs 1 (& 2 for LPT81)  
• Built-in Class B EMI filter  
Adjustment range  
Hold-up time  
Overload protection  
• Overvoltage protection  
• Overload protection  
Overvoltage protection  
Tracks outputs 1( & 2 for LPT81): 20%  
to 35% above output setting  
Environmental  
Logic Control  
Power Failure  
TTL Logic signal goes high 100-500  
msec after main output; it goes low at  
least 4 ms before loss of regulation  
Requires a contact closure to inhibit  
the outputs  
Compensates for 0.5 V lead drop min.  
Will operate without remote sense  
connected. Reverse connection  
protected.  
Operating temperature: 0° to 50°C ambient;  
derate each output at 2.5% per degree from 50° to  
70°C  
Remote inhibit  
Remote sense  
Electromagnetic susceptibility: designed to meet  
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3  
Humidity: Operating; non-condensing  
5% to 95%  
Vibration: Three orthogonal axes, sweep at  
1 oct/min, 5 min. dwell at four major resonances  
0.75 G peak 5 Hz to 500 Hz, operational  
Safety  
Storage temperature: -40° to 85°C  
VDE  
UL  
60950  
60950  
60950  
Temperature coefficient: ±.04% per °C  
CSA  
MTBF demonstrated: >550,000 hours at full load  
and 25°C ambient condition  
NEMKO 60950  
AUSTEL 60950  
CB  
CE  
Certificate & report  
Mark LVD  
1
Technical Support: (888) 41-ASTEC or (407) 241-2752  
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662  
rev 5.3.04  

与LPT81相关器件

型号 品牌 获取价格 描述 数据表
LPT82 EMERSON-NETWORKPOWER

获取价格

Power Factor Correction
LPT82 ASTEC

获取价格

80 Watts
LPT825/18NMOHF PULSE

获取价格

Solutions for Mobile Phone Antennas
LPT83 ASTEC

获取价格

80 Watts
LPT83 EMERSON-NETWORKPOWER

获取价格

Power Factor Correction
LPT85 INFINEON

获取价格

PHOTOTRANSISTOR
LPT85A INFINEON

获取价格

PHOTOTRANSISTOR
LPT9033-TR1 LIGITEK

获取价格

NPN SILICON PHOTOTRANSISTOR LED LAMPS
LPT-910-GB352 RCD

获取价格

PTC Thermistor, 91ohm, Through Hole Mount, AXIAL LEADED
LPT-910-GB352Q RCD

获取价格

PTC Thermistor, 91ohm, Through Hole Mount, AXIAL LEADED