LPF7032 SERIES
SMD Shielded type
■SHAPES & DIMENSIONS
■ELECTRICAL CHARACTERISTICS
RECOMMENDED PCB PATTERN
Rated Current(A)
Test
Freq.
(KHz)
Inductance
Inductance
TOL.(%)
DC Resistance
(Ω) 20%
(Dimensions in mm)
Ordering Code
IDC1
IDC2
(Ref.)
(µH)
(Max.)
PWEINDUCTORS
7.0 0.2
3.2 0.2
LPF7032T-3R3M
LPF7032T-4R7M
LPF7032T-6R8M
3.3
4.7
6.8
0.016
0.021
0.028
2.10
1.80
1.60
2.90
2.70
2.40
LPF7032T-100M
LPF7032T-150M
LPF7032T-220M
LPF7032T-330M
LPF7032T-470M
LPF7032T-680M
102
10
15
22
33
47
68
0.045
0.066
0.100
0.137
0.194
0.255
1.40
1.10
0.96
0.78
0.67
0.59
2.10
1.62
1.45
1.17
0.96
0.88
0.1
1.2
4.6
100
20
LPF7032T-101M
LPF7032T-151M
LPF7032T-221M
LPF7032T-331M
LPF7032T-471M
LPF7032T-681M
100
150
220
330
470
680
0.380
0.601
0.906
1.214
1.762
2.825
0.45
0.37
0.29
0.22
0.20
0.16
0.71
0.58
0.48
0.40
0.34
0.24
2.0
2.2
2.0
3.8
LPF7032T-102M
1000
4.292
0.13
0.19
■TEST EQUIPMENTS
• Inductance: Agilent 4284A LCR Meter (100KHz 0.5V)
■OPERATING TEMPERATURE RANGE
-20 ~ +85˚C (Including self-generated heat)
• Rdc: HIOKI 3540 mΩ HiTESTER
• Bias Current: Agilent 4284A + Agilent 42841A
• IDC1(The saturation current): △L ≤ 10% at rated current
• IDC2(The temperature rise): △T = 20˚C at rated current
LPF7045 SERIES
SMD Shielded type
■SHAPES & DIMENSIONS
RECOMMENDED PCB PATTERN
(Dimensions in mm)
■ELECTRICAL CHARACTERISTICS
Rated Current(A)
Test
Freq.
(KHz)
Inductance
Inductance
TOL.(%)
DC Resistance
(Ω) 20%
Ordering Code
IDC1
IDC2
(Ref.)
(µH)
(Max.)
7.0 0.2
4.5 0.2
LPF7045T-1R2M
LPF7045T-2R2M
LPF7045T-3R3M
LPF7045T-3R9M
LPF7045T-4R7M
LPF7045T-6R8M
1.2
2.2
3.3
3.9
4.7
6.8
0.0105
0.0190
0.0220
0.0250
0.0280
0.0390
5.00
3.00
2.50
2.40
2.30
1.90
4.20
3.40
3.20
3.00
2.80
2.04
330
0.1
LPF7045T-100M
LPF7045T-150M
LPF7045T-220M
LPF7045T-330M
LPF7045T-470M
LPF7045T-680M
10
15
22
33
47
68
0.0400
0.0560
0.0700
0.1100
0.1700
0.2800
1.80
1.50
1.30
1.10
0.90
0.75
1.81
1.50
1.30
1.11
0.93
0.76
1.2
4.6 0.1
100
20
2.0 0.1
2.2
2.0
3.8
LPF7045T-101M
LPF7045T-151M
LPF7045T-221M
LPF7045T-331M
LPF7045T-681M
100
150
220
330
680
0.3500
0.4800
0.7500
1.1000
2.1000
0.60
0.50
0.40
0.35
0.23
0.61
0.54
0.43
0.37
0.23
■TEST EQUIPMENTS
• Inductance: Agilent 4284A LCR Meter (100KHz 0.5V)
■OPERATING TEMPERATURE RANGE
-20 ~ +85˚C (Including self-generated heat)
• Rdc: HIOKI 3540 mΩ HiTESTER
• Bias Current: Agilent 4284A + Agilent 42841A
• IDC1(The saturation current): △L ≤ 10% at rated current
• IDC2(The temperature rise): △T = 20˚C at rated current
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before your order and/or use.
23