LM358M
ꢀ
ꢀ
ꢀ
Dual Operational Amplifiers
ꢀ
DESCRIPTION
The LM358 consists of two independent, high gain, internally frequency compensated operational amplifiers which were
designed specifically to operate from a single power supply over a wide range of voltages. Operation from split power
supplies is also possible and the low power supply current drain is independent of the magnitude of the power supply
voltage.
Application areas include transducer amplifiers, dc gain blocks and all the conventional op amp circuits.
FEATURES
PACKAGE INFORMATION
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Wide range of supply voltages
Low supply current drain independent of supply voltage
Low input biasing current
Low input offset voltage and offset current
Input common-mode voltage range includes ground
Differential input voltage range equal to the power supply voltage
DC voltage gain 100 V/ mV Typ
Internally frequency compensation
ELECTRICAL CHARACTERISTICS
at specified free-air temperature, Vcc = 5 V (unless otherwise noted)
LM358/ LM358M/ LM358MMK
PARAMETER
TEST CONDITIONS*
UNIT
mV
MIN
TYP MAX
VIO
Vcc = 5 V to MAX,
25 °С
3
7
9
Input offset voltage
VIC = VICR min,
Vo=1.4 V
Full range
αVIO
Full range
7
2
µV/°C
Average temperature coefficient of
input offset voltage
lIO
Vo=1.4 V
25 °С
50
nA
Input offset current
Full range
150
αlIO
Full range
10
pA/°C
Average temperature coefficient of
input offset current
IIB
Vo=1.4 V
25 °С
Full range
25° С
-20
-250 nA
-500
Input bias current
VICR
Common-mode input voltage range
Vcc = 5 V to MAX
0 to Vcc-1.5
0 to Vcc - 2
V
Full range
VOH
RL ≥2 KΩ (NOTE 1)
Vcc = MAX, RL=2 kΩ
Vcc = MAX,
RL ≥ 10 kΩ
RL ≥ 10 kΩ
25 °С
Full range
Full range
Vcc-1.5
26
27
V
High-level output voltage
28
5
VOL
Full range
20
mV
Low-level output voltage
AVD
Vcc = 15 V,
Vo=1V to 11 V,
RL ≥ 2 kΩ
25 °С
25
100
V/mV
Large-signal differential
voltage amplification
Full range
15
65
CMRR
Vcc = 5 V to MAX,
25 °С
80
dB
Common-mode rejection ratio
VIC = VICR min
kSVR Supply voltage rejection ratio
Vcc = 5 V to MAX
25 °С
25 °С
65
100
120
dB
dB
(∆Vcc/∆VIO)
Vo1 /Vo2
f=1 kHz to 20 kHz
Crosstalk attenuation
lo
Vcc = 15 V,
VID=1 V,VO= 0
Vcc = 15 V,
VID = - 1 V, Vo = 15 V
VID = - 1 V,
Vo =200 mV
25 °С
Full range
25 °С
Full range
25 °С
-20
-10
10
5
-30
20
mA
Output current
12
30
µA
lOS
Vcc at 5 V,
25 °С
±40
±60
mA
mA
Short-circuit output current
ICC
Supply current (two amplifiers)
GND at -5 V,Vo=0
Vo - 2.5 V, No load
Vcc = MAX,
Full range
Full range
0.7
1
1.2
2
Vo = 0.5Vcc, No load
•
All characteristics are measured under open-loop conditions with zero common-mode input voltage unless
otherwise specified. “MAX” VCC for testing purposes is 30 V. Full range is 0 °С to 70 °С.
Note1 Only for LM358
1